2- WITH
PANEL
Installation with Panel is described in the INSTALLATION INSTRUCTIONS, which are enclosed with the
bath.
This system avoids the need to provide an access hatch and ventilation grille. Access to the
hydromassage bath equipment for maintenance purposes is achieved by removing the skirting, and
ventilation is provided through the gap between the skirting and the floor. Under no circumstances should
this gap be sealed.
1.
The plumbing installation must comply with the corresponding regulations applicable in each
country.
2.
For the installation of taps, please consult the INSTALLATION INSTRUCTIONS corresponding to
each bath, which advise on how best to position them.
3 .
The automatic plug must be connected to the effluxion system by means of an elastic joint.
The electrical installation must comply with low voltage regulations and with the corresponding
regulations of each country.
1. Installation
Electrical connections must provide a minimum of Ipx5
rotection within volume 1. A connecting box (in accordance
with the protection established) is recommended. Care must
also be taken to make this connection at a height of more
than 20 mm above the floor.
No switches, power sockets or light fittings shall be installed
in volumes 0 and 1. Above these volumes it shall be
permissible to have sound control contactors operated by a
draw-cord or chain of non-hygroscopic material.
Switches shall not be installed in volume 2, however safety
power sockets can be installed. Fixed light fittings may also
be installed, preferably with category II insulation or, if
unavailable, install those which do not have any accessible
metallic part. In the lamp holders it shall not be possible to
make any accidental contact with live parts when inserting or
removing bulbs. In such light fittings no switches or power
sockets are allowed, except if these are safety power
sockets.
Volume 1
l
m
e
V
o
u
2
3
V
o
lu
e
m
V
ol
um
e
1
Volumen 0
V
lu
m
e
2
o
l
V
u
m
e
3
o
PLUMBING INSTALLATION
ELECTRICAL INSTALLATION
Volume 0
2. Wiring
The power cable used must be the one supplied with the bath or another of similar characteristics (with
the cover having characteristics not inferior to type H05 V V-F), taking into account the maximum voltage
2
stipulated in the low voltage regulations. The section of cable supplied is 1,5 mm .
Installation manual
Fig-3