SMART 200 TIG PULSE
27
3.3. Welding Operation
3.3.1 Argon Arc Welding Operation
TIG long welding
(
4T
):
t( s)
0
I( A)
Loosen the
switch
t1
t5
t7
Striking success
Stop arc
t3
t4
Base current setting
value
t2
t6
Loosen the
switch
Repress down the
switch
Start
current
Crater
current
Welding current (peak
current) setting value
Press and hold the
welding gun switch
Introduction
•
0
:
Press and hold the gun switch, Electromagnetic gas valve is turned on. The shielding gas starts to flow;
•
0
~
t1
:
Pre flow time, adjustment range of pre flow time :0,1~1.0S;
•
t1
:
Striking success, adjustment range of start current: 5~170 MMA
(
200A
);
•
t2
:
Loosen the gun switch, the output current slopes up from start current; if the output pulse function is
turned on, the output current is pulsed;
•
t2
~
t3
:
Output current slopes up to the setting current value; adjustment range of up slope time 0~5.0S ;
•
t3
~
t4
:
Welding process. During this period, the gun switch is loosen;
•
Note: If the output pulse function is turned on, the output current is pulsed. If the output pulse function is
turned off, the output current is DC current;
•
t4
:
Repress down the gun switch, the output current slopes down to crater current; if the output pulse
function is turned on, the slope down current is pulsed;
•
t4
~
t5
:
Down slope time, adjustment rang of down slope time: 0~5.0S;
•
t5
~
t6
:
Crater current holds time; adjustment range of crater current: 5~160A (200A);
•
t6
:
Loosen the gun switch, stop arc, and keep on argon flowing;
•
t6
~
t7
:
Post flow time, adjustment range of post flow time: 0,1
~
10.0S;
•
t7
:
Electromagnetic valve is closed and stop argon flowing. Welding is finished.
TIG short welding
(
2T
):
t( s)
0
I( A)
Loosen the
welding gun
switch
Press and hold the
welding gun switch
t1
t5
Striking
success
Stop arc
t3
t4
Base current setting
value
t2
Welding current (peak
current) setting value
5A
Introduction
:
•
0
:
Press and hold the gun switch, Electromagnetic gas valve is turned on. The shielding gas starts to flow;
•
0
~
t1
:
Pre flow time, adjustment range of pre flow time :0,1~1.0S;