GALA MIG 3000/3800.
21
3.3 OPERATION CONTROLS. GALA MIG 3800.
V
U
T
R
P
Q
P- DIGITAL VOLTMETER.
(Optional)
It measures the voltage of the welding circuit.
Q- DIGITAL AMMETER.
(Optional)
It measures the intensity of the welding circuit.
R- ON-OFF INDICATOR.
Equipment ON/OFF indicator light. It must stay ON when activating control N. If not, fuse T could have
"BLOWN", fault in the mains, etc.
T- FUSE-HOLDER.
Control circuit protection fuse system.
U- INCREMENTAL TAP-CHARGER.
This enables the correct welding voltage to be selected within the chosen range. It has 10 selection levels,
which will permit the best adjustment for each specific job.
V – ON/OFF SWITCH. SCALE SWITCH.
This switch is used to switch the power source on and also to select the regulation scale (2 scales).
3.4 WIRE-FEED UNITS. OPERATION CONTROLS.
In order to carry out a correct operation, please read the wire-feed units instructions manual.
4. MAINTENANCE OPERATIONS. RECOMMENDATIONS.
Before carrying out any operation on the machine or gun, we must place switch I of the equipment in "O"
position of machine disconnected. Specialized personnel must handle the machine to carry out maintenance
and repair operations
.
)
BLOW THE INSIDE OF THE MACHINE WITH COMPRESSED AIR FROM TIME TO TIME.
)
PLACE THE EQUIPMENT SOMEWHERE WHERE CLEAN AIR IS RENEWED.
)
KEEP THE MACHINE PANELS CLOSED.
)
DO NOT DISCONNECT THE MACHINE IF IT IS HOT.
)
KEEP THE WELDING GUN IN GOOD CONDITIONS FOR USE.