3
TOGGLE SWITCHES FOR MANUAL TESTING:
x
Toggle switches are provided for manual operation, diagnostics, and operational verification
regardless of the control wiring to the elevator controller
OVER-TORQUE AND OVER-SPEED DETECTIONS:
x
Over-torque and over-speed detection and restriction are parameterized for easy adjustment
to comply with codes
PLUG-AND-PLAY INFRARED DETECTOR EDGES:
x
Both NPN and PNP infrared detector edges can be connected directly to the VFE2500
simplifying electrical wiring and eliminating the need for an extra power supply
SPECIAL FEATURES ADDED:
x
Combined VVVF drive and main board makes the VFE2500 drive easily interchangeable from
one model or job to another
x
Additional I/O for special applications of:
Heavier door, Narrower door, Detector edges timeout for Nudging application, Buzzer output
for alarm before Nudging speed is applied
RELIABLE AND HIGH RESOLUTION FEEDBACK:
x
High resolution encoder and galvanic isolation techniques are used to deliver smooth, and
reliable operation.
x
Hardware and software encoder loss detections are employed to prevent run-away conditions
that could otherwise result in a closed-loop control system. This combination of hardware and
software provides an ultimate protection for human life
SERIAL COMMUNICATION TO VFE2500:
x
CAN (Controlled Area Network) or other communication protocols can be used to communicate
with VFE2500 serially.
x
CAN bus counter and analyzer are built in to monitor the CAN bus activities.
TROUBLESHOOTING ASSISTANCE DISPLAY:
x
The Faults display will explain to users the possible causes and shows the remedies for each
fault code.
MINIMUM CODE DISTANCE CLOSING TIME TABLES:
x
The minimum code distance closing time tables are available on the LCD keypad.
ACTUAL DISPLAY OF THE CLOSING TIME:
x
The actual code distance of the closing time is displayed to assist users in complying with
codes.
AUTO FALLBACK TO SLOW MODE IF SENSORS OR ENCODER FAIL:
x
If DOL, DCL, AUX, or DPM sensor fails, or if the encoder fails, the VFE2500 door operator will
continue to operate in slow scanning mode until repairs are completed
*: Door Protection Monitor is used in the Fault Monitor, which is a door lock and gate switch
protection device. Its purpose is to meet the ASME A17.1 RULE 210.15 and CAN/CSA-B44-M90
RULE 3.12.1.5. The Fault Monitor device can be purchased separately through ECI.
3
Содержание MOVFE 2500
Страница 1: ...2500 3069 1 888 425 2262 2500 3069 ELECTRICAL...
Страница 2: ...Rev 1 10 20 I...
Страница 24: ...19 6 DEFAULT PARAMETERS 19...
Страница 26: ...21 FAULTS AN EXAMPLE OF FAULTS DISPLAY COUNTERS 21...
Страница 27: ...22 USER LIST 22...
Страница 28: ...23 23...
Страница 29: ...24 24...
Страница 30: ...25 25...
Страница 31: ...26 MAXIMUM CLOSE SPEED AND FORCE 26...
Страница 32: ...27 ECI DEFAULT PARAMETER SETS 27...
Страница 34: ...29 SPEED PROFILES OF THE VFE2500 FOR NORMAL DOOR 29...
Страница 35: ...30 SPEED PROFILES OF THE MOVFE2500 FOR HEAVY DOOR 30...
Страница 36: ...31 SPEED PROFILES OF THE MOVFE2500 FOR NARROW DOOR 31...
Страница 91: ...Rev 10 20 85...
Страница 92: ......