Inputs:
6.
Outputs:
Four relays are provided to output DPM, RE-OPEN, DOL, and DCL signals to the elevator controller
in the form of contacts. The relay contacts are rated at 10Amp, 250VAC maximum and 100mA,
12VAC minimum.
Label Meaning
Remarks
DCL
Door Close
Limit
Door Close Limit
DOL
Door Open
Limit
Door Open Limit
REOPEN
Re-open
This output is used to flag the elevator
controller that the door(s) need to be
reopened. The reopen output DOES NOT
reopen the door directly. The signal to reopen
the door(s) must come from the elevator
controller. Re-open relay is triggered by any
one of the following detections:
- Stall Reverse; controlled by Par. 148.
- Frequency Failure; controlled by Par. 136.
- Detector Edges; controlled by Par. 202,
SW8, and Enable IC U5.
DPM
Door
Protection
Monitor
DPM is designed to work with the Fault
Monitor (FM). FM is a patented door lock and
gate switch protection device. Its purpose is
to meet the ASME A17.1 RULE 210.15 and
CAN/CSA-B44-M90 RULE 3.12.1.5. The
setting position of DPM is ½ inch before the
gate switch makes.
Three input modules are provided to receive OPEN, CLOSE,
and NUDGE commands from the elevator controller. These
universal input modules receive control signals either in
form of contacts or signal voltages; from 24-230V AC or
DC. Jumpers on the input modules must be removed if the
input signal voltage is 60V or less. LEDs of the input
modules draw currents from the elevator controller, not
from the VFE2500. Therefore, when these LEDs are lit, they
indicate that the elevator controller has sent commands.
In automatic mode, the VFE2500 will only accept input
signals from the elevator controller. In other words, open,
close or, (nudge + close) LEDs must be on to have the door
operator open, close, and nudge respectively.
7
Содержание MOVFE 2500
Страница 1: ...2500 3069 1 888 425 2262 2500 3069 ELECTRICAL...
Страница 2: ...Rev 1 10 20 I...
Страница 24: ...19 6 DEFAULT PARAMETERS 19...
Страница 26: ...21 FAULTS AN EXAMPLE OF FAULTS DISPLAY COUNTERS 21...
Страница 27: ...22 USER LIST 22...
Страница 28: ...23 23...
Страница 29: ...24 24...
Страница 30: ...25 25...
Страница 31: ...26 MAXIMUM CLOSE SPEED AND FORCE 26...
Страница 32: ...27 ECI DEFAULT PARAMETER SETS 27...
Страница 34: ...29 SPEED PROFILES OF THE VFE2500 FOR NORMAL DOOR 29...
Страница 35: ...30 SPEED PROFILES OF THE MOVFE2500 FOR HEAVY DOOR 30...
Страница 36: ...31 SPEED PROFILES OF THE MOVFE2500 FOR NARROW DOOR 31...
Страница 91: ...Rev 10 20 85...
Страница 92: ......