ĐŽŶƚĂĐƚΛƵŶŐƵĂƚŽƌ͘ĐŽŵͮƵŶŐƵĂƚŽƌ͘ĐŽŵ
16
03
23
_E
M
P2
en
chapter 2 - page 10
In addition to the coupling, required for transferring from a 300 ml or 500 ml jar into a smaller
jar, both the spindle and the AirDynamic may also be used. Dispensing and transferring a
formulation via the regular jar nozzle from a 1000 ml and 2000 ml jar is practically only possible
using the AirDynamic.
We recommend transferring the formulation after mixing as soon as possible, since the formu-
lation is still warm and less viscous.
gako unguator AirDynamic
The gako unguator AirDynamic optimizes batch preparation
within the closed system:
• Contamination-free transfer
• Contamination-free storage
The AirDynamic has been designed to apply with jars from
size 300 ml to 2000 ml to extract compounds. An adapter
connected to a pump ball is a
ffi
xed to the center hole on the
body’s bottom of the jar with an air-tight connection.
By pumping air into the lower chamber of the jar using the pump ball, the pressure thus gene-
rated moves the bottom upward. Thanks to the AirDynamic, even thick pastes can be dispensed
via the small dispensing opening in the screw cap or transferred to small jars using the coupling.
The material outlet velocity depends on viscosity which may be reduced through warming.
The air pressure that had developed in the lower chamber of the jar can be relieved by opening
the valve screw.
This is mandatory after the transfer process using the coupling before the smaller jar is
removed. Otherwise this may result in considerable contamination of the immediate environ-
ment, depending on the formulation viscosity.
gako unguator ExactDose Adapter
The gako unguator ExactDose Adapter allows the exact dosage of 0.5
ml paste, gel, cream or ointment for topical or transdermal therapy.
The adapter will be screwed onto the jar after the mixing process is
fi
nished. Insert the red set screw with a little pressure into the trans-
parent part of the ExactDose Adapter.
The coloured ball inside the ExactDose Adapter lays on its lowest posi-
tion when the red set screw is horizontally positioned.
pic.: gako unguator AirDynamic
Abb.: gako unguator Exact-
Dose