background image

SS91BV-M GSM Intercom             

18                                       

Revision E8

 ,Jan 2015

 

User commands table   

You can program many different user command codes in one text message with SMS command 

format. *12*1234 # [command Code1] # [command Code 2] # [command Code3] 

#........ 

 

No. 

Feature 

Command   

Description 

Default 

Change programming   

Password 

01 [ password ] # 

password:4 digit codes 

1234 

Change access control 

password 

02 [ password ] # 

password:4 digit codes 

5678 

Change monitoring mode 

password 

03 [ password] # 

password:4 digit codes 

1212 

Store a call button phone 

number 

1 [ Y ] [ phone number ] # 

 

Y= phone number 1,2 or 3 

Max 3 phone numbers 

phone No.:3~15 digit codes 

None 

Delete a call button   

Phone number 

1[ Y ]*# 

Y= phone number 1,2 or 3 

phone No.:3~15 digit codes 

None 

Speaker Volume 

3 [ speaker volume] # 

speaker volume level:0 ~ 4   

Microphone Volume 

4 [ microphone volume] # 

microphone volume level:0 ~ 4   

Relay Time 

51 [ relay time ] # 

relay time: 1~9999 sec 

Call no answer time and 

divert to next number 

52 [ no answer time ] # 

No answer time :10~99 sec 

 

20 sec 

10 

Max call Time 

53 [ max call time] # 

Max call time:005~999 sec 

060 sec 

11 

Max monitoring time 

55[ duration time] # 

duration time:00 ~ 60 mins   

00 ( no limit) 

10 mins 

12 

Change relay trigger code 

61 [ X ] # 

X=0~9 / * /

 

13 

Change rely hold code 

63 [ X ] # 

X=0~9 / * /

 

14 

Change relay release code 

64 [ X ] # 

X=0~9 / * /

 

 

15 

 

Ring in to open the door 

(Max: 100 numbers) 

71 [ country code ] #   

72 [ phone number ] # 

73 [delete phone number ] # 

73*#   

Country code:1~3 digit codes 

Number: 3~15 digit codes 

Delete number: 3~15 digit codes 

Del all phone numbers

 

886 

 

16 

Add administrator phone 

number 

74 [ admin number ] # 

 

admin number: 

3~15 digit codes

 

( no number no restriction)   

None 

17 

Del administrator phone 

number     

74*# 

delete administrator phone 

number   

None 

18 

Reset 

999# 

reset default 

None 

 

Содержание SS91BV-M

Страница 1: ...com 1 Revision E8 Jan 2015 GAINWISE TECHNOLOGY MANUAL DOORINTERCOM SS91BV M SS1204AV M GSM WCDMA INTERCOM ACCESS CONTROL SYSTEM For your protection read these instructions completely And keep them for...

Страница 2: ...7 SS91BV M GSM INTERCOM OPERATION 8 Enter Listener Monitoring Mode 10 Enter Access Control Mode 10 Enter Programming Mode 10 Programming 11 Door Gate Release 12 Check GSM Signal Strength 14 Check Rela...

Страница 3: ...roduct 2 Unplug all the connections of product before cleaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning 3 Do not use this product near water 4 Do not use this produ...

Страница 4: ...ile call with you During the call you will be able to activate realty This SS91BV M GSM Intercom gives you the opportunity not only to know who is waiting at the entrance from a remote location but al...

Страница 5: ...sion E8 Jan 2015 INSTALLATION This GSM Intercom is suitable for both flush and surface mounting Note For surface mounting you will have to remove the plastic enclosure before fitting main station into...

Страница 6: ...SS91BV M GSM Intercom 6 Revision E8 Jan 2015 SS91BV M GSM Intercom Unit Wiring Diagram Call Button Speaker Microphone...

Страница 7: ...is OFF before inserting the SIM card Carefully side the SIM holder in the OPEN direction insert the SIM and slide in the CLOSED direction to lock it in place 2 Antenna Install the antenna as high as p...

Страница 8: ...ith the visitors During conversation press on your mobile for door open The relay switches can also be temporarily or permanently switched on or off by press and 1 Enter system menu There are three di...

Страница 9: ...SS91BV M GSM Intercom 9 Revision E8 Jan 2015...

Страница 10: ...fined numbers 3 You will hear a Do tone to enter access control mode by pressing 33 5678 where 5678 is the password 4 The door will be opened after enter the correct password To open the door by passw...

Страница 11: ...SMS must start with the pass code default 1234 in the following format 12 1234 Followed immediately by a command 4 To program a call button numbers DO NOT enter country code just the complete number a...

Страница 12: ...se the following commands to program the unit Insert international country code 1 3 digits 71 country code Add a number up to 100 numbers 72 telephone number Delete a number 73 telephone number Delete...

Страница 13: ...ng in to open SMS format to delete phone number 1 and 2 12 1234 730865683624 730865682554 SMS format to delete all numbers 12 1234 73 After the numbers are programmed you can also send the text messag...

Страница 14: ...tatus SMS format 22 SMS Reply Relay ON Detect ON Relay Hold Detect GND Remark Terminal mark Detect see wiring diagram is for you to connect a door reed switch The gates would have a reed switch wired...

Страница 15: ...ches 100 numbers default N 1 sending when it reaches 200 numbers Max Sending record when it reaches 100 numbers command code example 12 1234 830 2 Way of sending dial in numbers record via e mail or S...

Страница 16: ...1234 85 11 SIM card number of SS91BV M for Clock date and time correction 12 1234 86 SIM No of SS91VB M 12 To delete SIM card number of SS91BV M for Clock date and time correction 12 1234 86 Remark w...

Страница 17: ...ease relay for door close 5678 User commands to check system info control relay via SMS No Function Command Reply 1 check signal strength 20 Signal Level 0 31 from poor to best Service provide name ne...

Страница 18: ...me level 0 4 3 7 Microphone Volume 4 microphone volume microphone volume level 0 4 3 8 Relay Time 51 relay time relay time 1 9999 sec 1 9 Call no answer time and divert to next number 52 no answer tim...

Страница 19: ...o 24 Volt AC DC Operating Current Maximum 250 mA Typically 55mA GSM WCDMA Module Cinterion Simcom GSM WCDMA Frequency GSM 850 900 1800 1900 Mhz WCDMA 850 1900 or 900 2100 Mhz Physical size Face plate...

Страница 20: ...number for dial in door release you NEED TO enter country code Command to use 12 1234 71 country code 72 phone number 72 phone number 72 phone number Example Ireland Country code 353 UK 44 USA 1 086 5...

Страница 21: ...ct that the centre pin inside the antenna is intact and has not been pushed back inside the fitting Q The unit calls the first number but there is not enough time to answer before it diverts to the ne...

Страница 22: ...ps on checking and improving reception Q The or key does not work when the intercom calls a phone A Check if you can hear the relay clicking at the gate when the or key is pressed during a call If it...

Отзывы: