A maximum of 16 Model LE200-RMs can be connected within a single zone or Page/Party
®
subsystem.
Avoid having more than one Model LE200-RM connected to a particular Page/Party
®
cable. Instead,
use the LVDS link whenever possible.
Line extenders can NOT be wired in a loop architecture for redundant connections as shown below:
Figure 12. Invalid Loop Connection of Page/Party
®
Systems
All contact input states are ORed together to determine a contact output state.
All remote page line audio detected states are ORed together to determine the state of the page line
audio detected relay contact output.
All remote page line ground fault states are ORed together to determine the state of the page line
ground fault relay contact output.
When enabled, 50 kHz VLC signal on any page line is transmitted to all page lines.
SmartSeries FSK data on any page line is transmitted to all page lines.
Manual retraining of echo cancellation at one Model LE200-RM also requests it at all digitally
interconnected Model LE200-RMs.