CommandPLUS Series Desktop Console Installation and Service Manual Features and Options
43
09/07
Supervisory Mounting
1.
Disconnect the power from the CommandPLUS Series Desktop Console and remove all attached cables
from the rear cover.
2.
Mount the Telco Interface to the Supervisory unit on the rear of the console. Refer to Figure 19.
Position the Telco Interface so that the three DB25 connector plugs line up with the DB25 connector
receptacles on the rear panel.
3.
Secure the Telco Interface with the supplied #6-32 screws shown in Figure 19, tightening them until the
unit is snug against the rear panel.
4.
Plug one end of a standard DB50 connector plug into the single 50-pin Telco connector and terminate
the other end to an applicable punch block. Place the connector bracket over the 50-pin connector and
secure with two screws. The bracket secures the connector to the Telco Interface.
5.
Reattach all cables and reconnect the power.
N
OTE
:
The Supervisory unit input connectors and output connectors can each have a separate Telco
Interface unit attached.
Figure 19.