CommandPLUS Series Desktop Console Installation and Service Manual Features and Options
37
09/07
Table 13.
Pin Connect
to:
Description
CommandPLUS
DB25
(Printer)
DB9 (PC)
Ground 9 7 5
TX Data
10
3
2
RX Data
11
2
3
DSR 13
11
4
DTR 14 6
6
Logging Recorder Output Module
This standard feature consists of an additional board that is installed in the CommandPLUS. This feature
adds a logging recorder output that provides a line-level sum of the transmit mic audio, paging tones,
receive audio, parallel console audio, and all signaling. This 600-ohm balanced output should be connected
to a suitable logging recorder to record all audio activity taking place on the console. Refer to Figure 2 in
this manual for the Logging Output connector location on the rear panel.
N
OTE
:
The signaling control/module (MDC1200 option) and the logging recorder output module are
mutually exclusive. If signaling control is required, the logging recorder module must be removed because
they both occupy the same board location. These two features can not co-exist.