16
9.
Screw the new main control nozzle for the outer
burner ring w1 as far as it will go into the nozzle
retaining head.
10.
Fit the nozzle retaining head onto the burner
pipes.
11.
Fit the securing clips.
Adjusting the main control nozzles on the wok
burner
1.
Unscrew the fastening screw.
→
2.
Adjust the air regulating valve to the correct set-
ting.
The setting depends on the gas type →
.
3.
Tighten the fastening screw.
Adjusting the main control nozzles on the standard
output burners and high output burners
1.
Unscrew the fastening screw.
2.
Adjust the air regulating valve on the outer burner
L1 →
to the correct setting.
3.
Tighten the fastening screw.
4.
Adjust the air regulating sleeve on the inner
burner L2 →
to the correct setting by turn-
ing or pushing it.
→
Screwing the hob in place
▶
Put the hob in place and tighten the screws
evenly.
Fitting burner parts
▶
Fit the burner parts and position them correctly.
→
Fitting the pan supports
▶
Fit the pan supports and position them correctly.
→
Switching gas type using the control knob
1.
Turn the control knob to 0.
→
2.
Disconnect the appliance from the mains power
supply.
→
3.
Wait at least 30 seconds.
4.
Reconnect the appliance.
→
a
The illuminated ring around the control knob lights
up green for a few seconds and then yellow.
→
5.
Wait until the illuminated ring goes out.
6.
While the control knob is pushed in, carry out the
following steps without interruption:
‒
Turn the control knob one notch anti-clockwise
to 12 .
‒
Turn the control knob three notches clockwise
to 1 .
‒
Turn the control knob two notches anti-clock-
wise to 0 .
a
The illuminated ring on the control knob lights up
yellow.
7.
Set the gas type on the control knob.
→
If the control knob is on the gas type currently set,
the illuminated ring on the control knob lights up
green.
Control knob position
Gas type
2
G20-20 mbar/G25-25
mbar
3
G30-29 mbar/G31-37
mbar
4
G30-50 mbar
6
G25-20 mbar
8.
Leave the control knob at the required setting for
at least 5 seconds.
a
The illuminated ring around the control knob lights
up green.
9.
To save the setting, while the control knob is
pushed in, carry out the following steps without in-
terruption:
‒
Turn the control knob to 0 .
‒
Turn the control knob one notch anti-clockwise
to 12 .
‒
Turn the control knob three notches clockwise
to 1 .
‒
Turn the control knob two notches anti-clock-
wise to 0 .
a
The illuminated ring goes out.
a
The setting has been saved.
a
The illuminated ring around the control knob lights
up yellow for a few seconds.
10.
Wait until the illuminated ring goes out.
Checking that the appliance is working after con-
version
1.
After converting the gas type, check the appliance
for leaks.
2.
Make sure that yellow tips are not visible on the
flames.
3.
When turning the control knob quickly between
the highest and the lowest setting, make sure that
the burner does not go out and that no flashback
occurs.
Documenting the gas type conversion
▶
Attach the sticker showing the new gas type next
to the rating plate on the appliance.
es
Volumen de suministro
Al desembalar el aparato, comprobar que estén to-
das las piezas y que no presenten daños ocasiona-
dos durante el transporte.
→
Distancias de seguridad
Respetar las distancias de seguridad del aparato.
→
*La distancia de 700 mm se aplica para el montaje
debajo de una campana extractora. Para el montaje
debajo de un armario superior fabricado con mate-
rial inflamable, la distancia mínima es de 760 mm.
Medidas del aparato
Aquí se pueden consultar las dimensiones del apa-
rato.
→
Содержание VG415115F
Страница 2: ...2 6 7 8 9 10...
Страница 3: ...3 11 12 13 14 15 16 17...
Страница 4: ...4 18 19 20 21 22 23...
Страница 5: ...5 24 25 26 27 28 29 30...
Страница 6: ...6 31 32 33 34 35...
Страница 42: ...42...
Страница 43: ...43...
Страница 44: ...44...