7
The subsurface must be level and even in order to ensure
that the appliance is securely installed and works correctly.
The subsurface must be made from a hard, non-flexible
material.
The floor of the installation space must be the same height
as the rest of the space.
On account of the weight of a fully-laden appliance,
it is necessary to have a bearing subsurface.
In the case of doubt, the help of architect or specialist
builder should be enlisted.
Electrical connection
Do not use extension cables or distributors.
This appliance must be connected to a permanent socket.
The socked for connecting the appliance must be freely
accessible. Connect the appliance only to 220–240 V/
50 Hz AC current via a socket which has been properly
installed. The socket must be fused with a 10 to 16 A fuse.
For appliances operated in non-European countries,
the identification plate should be checked to see whether
the electric voltage and type of current match those
of the mains supply. The power cable must only
be replaced by a technician.
m
Warning
On no account should the appliance be connected
to electronic energy saver plugs or to converters which
convert DC current to 230 V AC (e.g. solar appliances,
marine on-board power supplies).
Water connection
m
Caution
Connect the appliance to a cold water pipe only.
A cold water connection is necessary for operating
the automatic ice maker.
The appliance must be installed in accordance with
AS/NZS3500.1 and AS/NZS3500.2.
The maximum water temperature should not exceed 40 °C.
The water pressure must lie between 0.17 and 0.5 MPa
(1.7 and 5 bar). The installation must correspond to the local
plumbing regulations.
A separate shut-off valve should be installed in the
coldwater inflow.
The shut-off valve should not be located behind the
appliance. It is recommended that you fit the shut-off valve
directly next to the appliance or at another place which
is easily accessible.
When installing the water connection, pay attention
to the permissible installation area for the water pipe.
For more information concerning the permissible installation
area, see the section “Dimensions of the installation”.
Note, if the water line for the cold water connection
is not included in the product package:
–
For connection to the drinking water mains use only
water pipes which are suitable for drinking water.
Observe national regulations and the connection
conditions of the local water supply companies.
–
The maximum outside diameter of the water pipe
(without connecting pieces) is 10 mm.