21
6.
Attaching the anti-tipping brackets
to the wall
m
Warning
Ensure that in the wall area there are no electrical
wires or pipes which could be damaged by pipes.
Risk of injury or damage!
Information on anti-tipping device:
–
For each appliance, two anti-tilt ribs are needed.
–
In the case of a Side-by-Side combination, a total
of two anti-tilt ribs are used.
–
The set supplied, contains fastening screws
for various subsurfaces. Select the fastening
screws corresponding to the local conditions.
–
If it is not possible to securely fasten the anti-tilt ribs
and consequently, not possible to securely fasten
the appliance using the fastening screws supplied,
select another suitable method for securely fastening
the anti-tilt ribs.
–
In the case of some fitted shapes, it may be necessary
to screw in at an angle the wood screws used
to fasten the anti-tilt ribs to the rear wall.
z
Determine the fastening points of the anti-tilt ribs.
Determine the actual dimensions according
to the section “Dimensions of the installation”.
z
If a installation niche is deeper than the appliance,
lay a strong wooden plank behind the anti-tilt ribs
and screw tightly to the subsurface or the wall.
The length of the plank should correspond to the
width of the installation niche!
Important note:
As far as possible, always screw the wooden plank
to the rear wall of the niche.
Subsurface wooden floors
The wood screws (5 x 60 mm and 4 x 15 mm) which
are supplied should be used for wooden floors.
z
Drilling guide holes:
3 mm for the wood screws (5 x 60 mm)
2 mm for the wood screws (4 x 15 mm)
Ensure that the screws 5 x 60 at least take a hold
(19 mm) in the solid subsurface.
z
Tightly screw the anti-tilt ribs. Re-examine to make
sure that the screws are firmly tightened.
Subsurface concrete
m
Warning
When installing or working with floor anchors always
use protective glasses and other protective equipment
or protective clothing – risk of injury!
Floor anchors are not suitable for use in connection with
lightweight construction masonry, breeze blocks or tiles.
Never use floor anchors in fresh concrete which has not
hardened.
In drilling holes for these floor anchors, do not use core
drills.
Use a floor anchor M8 and a screw M8.
Additionally use the (5 x 60 mm and 4 x 15 mm)
woodscrews supplied.
z
Drill a hole with a 10 mm diameter having a depth
a little more than the raising depth.
Use the drill supplied.
z
Clean the hole or drill a little deeper.
Содержание RC 462 AU
Страница 1: ...Gaggenau en Installation instruction RC 462 AU RF 463 AU RW 464 AU ...
Страница 2: ...2 ...