background image

6

The Instructions for Use apply to several versions of
this appliance. Accordingly, you may find
descriptions of individual features that do not apply
to your specific appliance.

This extractor hood complies with all relevant safety
regulations.

Repairs should be carried out by qualified
technicians only.

Improper repairs may put the user at considerable
risk.

Before using your appliance for the first time,
please read these Instructions for Use carefully.
They contain important information concerning your
personal safety as well as on use and care of the
appliance.

Please retain the operating and installation
instructions for a subsequent owner.

This appliance is labelled in accordance
with European Directive 2002/96/EG
concerning used electrical and electronic
appliances (waste electrical and electronic

equipment – WEEE). The guideline determines the
framework for the return and recycling of used
appliances as applicable throughout the EU.  

Remove the packaging from the appliance and
dispose of it properly. Pay attention to the fact that
there are accessories in the packaging.
Keep packaging elements out of the reach of
children!

Thoroughly clean the appliance before using it for
the first time.

Before operating the appliance for the first time,
check that the mains connection is in proper
working order.

In the event of malfunctions, first of all check the
household fuses. If the problem has nothing to do
with the power supply, please contact your
specialist dealer or your local Gaggenau after-sales
service.

If an F appears in the display :

See "Filters and maintenance" Section.

If is not possible to operate the extractor hood:

Disconnect the extractor hood from the mains
electricity supply by pulling out the plug or
switching it off at the main fuse box.
Wait for approx. 1 minute and then switch it on
again.

If you have any questions or if a fault occurs, please
call Customer Service. 

(See list of Customer Service representatives).

When you call, please quote the following:

Enter the relevant numbers into the box above. The
E-Nr. (product no.) and FD (production date) are
shown on the nameplate which can be seen inside
the extractor hood after the filter frame has been
detached.

The manufacturer of the extractor hoods

accepts no liability for complaints which can be
attributed to the design and layout of the
pipework.

Operating for the First Time

If you encounter a problem

E-Nr.                       FD

Содержание AI 280720

Страница 1: ...Extractor hood AI 280720 Gaggenau Operating and installation instruction...

Страница 2: ...settings b Always turn hood on when cooking at high heat or when cooking flaming foods c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan...

Страница 3: ...ng procedure 8 Intensive setting 9 Special functions 9 Filters and maintenance 10 Grease filters 10 Saturation indicator F 10 Activated carbon filter 11 Cleaning and care 12 Replacing the light bulbsn...

Страница 4: ...easures such as reciprocal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by...

Страница 5: ...racted particularly well at the front of the cooking field The Coanda effect may allow you to operate the extractor hood at a lower quieter level than you were previously accustomed to The Coanda air...

Страница 6: ...ging elements out of the reach of children Thoroughly clean the appliance before using it for the first time Before operating the appliance for the first time check that the mains connection is in pro...

Страница 7: ...user Do not place any heavy objects on the appliance Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits Isolate the appliance...

Страница 8: ...ight Fan follow on Intensive setting The most effective method of removing vapours produced during cooking is to Switch the ventilator ON as soon as you begin cooking Switch the ventilator OFF a few m...

Страница 9: ...l running time to 3 5 or 10 minutes by simultaneously pressing the Int key and the 1 2 or 3 key and you can store this setting When delivered the appliance is set to five minutes i e the combination o...

Страница 10: ...has not started to flash Cleaning the metal grease filters In normal operation 1 to 2 hours daily the metal grease filter must be cleaned 1 x a month The filters can be cleaned in a dishwasher It is h...

Страница 11: ...moving and inserting the metal mesh grease filters 2 Insert the activated carbon filter 3 Insert the metal grease filters see Removing and inserting the metal grease filters Replacing the activated ca...

Страница 12: ...sk of fire and ensures that the extractor hood continues operating at maximum efficiency Clean the operating buttons with a mild soapy solution and a soft damp cloth only Do not use stainless steel cl...

Страница 13: ...a risk of being burnt 2 Remove the metal mesh filters see Removing and inserting the metal mesh grease filters 3 Loosen the screws for the mounting rails 4 Carefully remove the glass panes 5 Remove t...

Страница 14: ...9 Tighten the screws for the mounting rails 10 Insert the metal grease filters see Removing and inserting the metal grease filters 11 Restore the power by inserting the mains plug or switching on the...

Страница 15: ...haust air shaft or directly into the open through the outside wall It is not allowed to pass the exhaust air into a flue or exhaust air chimney that is in operation or into a shaft that is linked to t...

Страница 16: ...The extractor hood must not be installed over a solid fuel cooker a potential fire hazard e g flying sparks unless the cooker features a closed non removable cover and all national regulations are obs...

Страница 17: ...such as gas oil or coal fired heaters continuous flow heaters hot water boilers care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combus...

Страница 18: ...ch can be attributed to the design and layout of the pipework Round pipes We recommend Internal diameter 6 Flat ducts must have an internal cross section that equates to that of round pipes There shou...

Страница 19: ...od should only be connected to an earthed socket that has been installed according to relevant regulations If possible site the earthed socket directly behind the chimney panelling The earthed socket...

Страница 20: ...es 5 16 for the wall plugs Push the plugs flush with the ceiling 3 Turn two screws to a 25 64 gap Both screws are placed in a position in which at a later stage of the installation the key holes of th...

Страница 21: ...nd attach it with all 4 screws to the ceiling Circulating air mode only assemble the circulating air switch module and fix it to support frame Cut the flexible air pipe to the required length and fix...

Страница 22: ...chimney duct unit which has no magnetic strips with 2 screws on the top of the support frame 14 The second top chimney duct which has magnetic strips should be slightly bent open in order to slide ov...

Страница 23: ...23 KF001 010...

Страница 24: ...nau 5551 McFadden Avenue Huntington Beach CA 92649 Telephone 877 4GAGGENAU USA www gaggenau usa com Gaggenau Hausger te GmbH Carl Wery Stra e 34 81739 M nchen Germany www gaggenau com 9000384450 EB 88...

Отзывы: