manualshive.com logo in svg
background image

Use, Care, and Installation Guide

www.zephyronline.com

Model number: 

Serial Number: 

Date of Purchase: 

Sales Dealer: 

JAN11.0601 © Zephyr Corporation

Pyramid

ZPY-E30AB, AW, AS
ZPY-E36AB, AW, AS

Tamburo

ZTA-E30AS
ZTA-E36AS

Terazzo

ZTE-E30AS
ZTE-E36AS

Содержание Essentials Terazzo ZPY-E30AS290

Страница 1: ...allation Guide www zephyronline com Model number Serial Number Date of Purchase Sales Dealer JAN11 0601 Zephyr Corporation Pyramid ZPY E30AB AW AS ZPY E36AB AW AS Tamburo ZTA E30AS ZTA E36AS Terazzo ZTE E30AS ZTE E36AS ...

Страница 2: ...www zephyronline com ...

Страница 3: ...ng Height Clearance 6 Ducting Options 7 Specifications 8 Preparing Electrical 9 Preparing Ducting Location 10 Recirculating 11 Optional Utensil Bar 12 Mounting the Range Hood 13 CONTROLS Slide Controls 14 MAINTENANCE Cleaning and Filter Removal 15 Lights 16 TROUBLESHOOTING 17 LIST OF PARTS AND ACCESSORIES 18 ...

Страница 4: ...e for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned...

Страница 5: ...tomer s responsibility To contact a qualified electrical installer To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a...

Страница 6: ...0 rectangular collar with damper 1 Utensil bar 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Philips head screwdriver with minimum 8 long shaft required to install ZPY E30 Cable lock if required by local codes Recirculating kit Suction Cup 1 For Light Bulb Installation and Removal M4 x 3 4 4 M4 x 1 1 4 4 M4 x 8 6 M4 x 8 2 Wire Caps 3 For...

Страница 7: ...ound straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round roof cap 30 Ft x Ft 7 or 8 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork 6 roundto 3 1 4 x 10 rect tran...

Страница 8: ...than 32 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will lose its performance and efficiency If available also refer range manufacturer s height clearance requirements and recommended hood mounting height above range Vertical Ducting 7 round minimum or 3 1 4 ...

Страница 9: ...cs or garages All exhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Soffit or crawl space Roof Pitch w Flashing Cap Rear Ducting Side wall cap w gravity damper ductless recirculating Tamburo Terazzo Pyramid ...

Страница 10: ...l Heights 12 7 3 8 7 5 8 9 16 1 9 16 3 3 8 21 1 8 Back 3 1 4 7 16 8 11 16 9 15 16 1 3 16 elec k o CL 3 1 4 7 16 8 11 16 9 15 16 1 3 16 7 3 8 Top 29 15 16 4 5 8 25 3 16 8 2 8 11 16 6 15 16 3 1 4 1 9 15 16 elec k o 1 15 16 31 1 8 or or 35 15 16 CL Adjustable Utensil Rail Heights 10 1 4 8 1 4 Tamburo Terazzo Note Installation dimensions are the same for Pyramid Tamburo and Terazzo ...

Страница 11: ...evailing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please refer to Electrical Diagram labeled on product Cable Lock A cable locking connector not supplied might also be required by l...

Страница 12: ...of hood 1 Using a flat head screwdriver remove only the rectangular section of the knock out plate located on top of hood 1 Using a flat head screwdriver remove the rectangular knock out plate located on back of hood 2 Secure 3 1 4 x 10 rectangular collar to top of hood using 6 M4 x 8 screws 2 Secure 3 1 4 x 10 rectangular collar to back of hood using 6 M4 x 8 screws 2 Secure 7 round collar to top o...

Страница 13: ...s first to install brackets and center panel then re install screws 3 Install charcoal filters into charcoal filter brackets 4 Install the mesh filters Note To use hood in air recirculating mode please purchase recirculating kit ZRC 0200 charcoal filter bracket center panel charcoal filter bracket 1 Remove air diverter plate slot covers Remove metal air diverter plate from front slot and re position to ...

Страница 14: ...abinet There are 3 height options for installing the utensil bar Install utensil bar and adjust the height before mounting the hood Utensil bar should press against the wall when hood is installed S Hooks 1 Secure utensil bar to back of hood using 2 M4 x 8 utensil bar screws 2 Install optional s hooks used to hang utensils Fig 1 Fig 2 ...

Страница 15: ...ion Measure and mark the mounting holes duct and electrical locations with a pencil 6 Drill cut out the required openings for duct and electrical access make sure the duct opening is large enough to apply duct tape 7 Fasten hood onto cabinet with 4 M4 wood screws provided 8 Install electrical 9 Install duct work and seal with duct tape 10 Reinstall mesh filters 11 Power up hood and check for leaks ...

Страница 16: ...ine com 0 I I I I I I Blower On Off Speed Selection 1 Lights Off Bright Dim 2 0 I I I BLOWER ON OFF SPEED SELECTION 0 is off I is low speed II is medium speed and III is high speed LIGHTS OFF BRIGHT DIM 0 is off I is bright and II is dim 1 2 ...

Страница 17: ...Always scrub lightly using a micro fiber or clean cotton cloth and with grain Metal Mesh Filters The aluminum mesh filters are intended to trap residue and grease from cooking Although the aluminum mesh filters should never need replacing they are required to be cleaned every 30 days or more often depending on cooking habits Filters may be placed in dishwasher at low heat or soaked in hot soapy water...

Страница 18: ... and bulbs are not hot Remove by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach suction cup included in hardware package or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type MR16 GU 10 50W halogen For Zephyr ...

Страница 19: ...the capacitor The unit is vibrating 1 The blower is not secure in place 1 Tighten the blower in place 2 Damaged blower wheel 2 Change the blower 3 The hood is not secured in place 3 Check the installation of the hood The motor is working but the lights are not 1 Defective halogen bulb 1 Change the halogen bulb 2 The light bulb is loose 2 Tighten the light bulb The hood is not venting out properly ...

Страница 20: ...ement Parts Light Bulb MR16 GU10 50W each Z0B 0020 Mesh Filter All Models each 50200030 Optional Accessories Recirculating Kit All Models ZRC 0200 Charcoal Filter Replacement each Z0F C002 To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 ...

Страница 21: ...r all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE EXCLUSIVE AND IN L...

Отзывы: