FIRST AID MEASURES

 

 

Eye: 

No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water.

 

Skin: 

No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove the material 

from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.

 

Ingestion: 

No specific first aid measures are required. Do not induce vomiting. As a precaution, get medical advice.

 

Inhalation: 

No specific first aid measures are required. If exposed to excessive levels of material in the air, move the exposed person to 

fresh air. Get medical attention if coughing or respiratory discomfort occurs.

 

Note to Physicians: 

In an accident involving high

-

pressure equipment, this product may be injected under the skin. Such an accident 

may result in a small, sometimes bloodless, puncture wound. However, because of its driving force, material injected into a fingertip can 

be deposited into the palm of the hand. Within 24 hours, there is usually a great deal of swelling, discoloration, and intense throbbing 

pain. Immediate treatment at a surgical emergency center is recommended.

 

 

FIRE

 

 

Leaks/ruptures in high pressure system using materials of this type can create a fire hazard when in the vicinity of ignition sources (e.g. 

open flame, pilot lights, sparks, or electric arcs).

 

 

FLAMMABLE PROPERTIES:

 

Flashpoint: 

(Cleveland Open Cup) 178 °C (352 °F) Minimum

 

 

EXTINGUISHING MEDIA: 

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

 

 

PROTECTION OF FIRE FIGHTERS:

 

Fire Fighting Instructions: 

This material will burn although it is not easily ignited. See Section 7 for proper handling and storage. For fires 

involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self

-

contained breathing 

apparatus.

 

Combustion Products: 

Highly dependent on combustion conditions. A complex mixture of airborne solids, liquids, and gases including 

carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.

 

 

ACCIDENTAL RELEASE MEASURES

 

 

Protective Measures: 

Eliminate all sources of ignition in vicinity of spilled material. 

 

Spill Management: 

Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, 

surface water or groundwater. Clean up spill as soon as possible. Use appropriate techniques such as applying non

-

combustible 

absorbent materials or pumping. Where feasible and appropriate, remove contaminated soil. Place contaminated materials in disposable 

containers and dispose of in a manner consistent with applicable regulations.

 

 

ECOLOGICAL INFORMATION

 

 

Waste disposal: 

In accordance with all environmental regulations applicable to your area.

 

 

Spillage: 

Prevent entry into drains, sewers and water course. Soak up with diatomaceous earth or other inert material. Store in 

appropriate container for disposal.

 

 

Ecotoxicity: 

This material is expected to be harmful to aquatic organisms and may cause long

-

term adverse effects in

 

the aquatic environment. The ecotoxicity hazard is based on an evaluation of data for the components or a similar material.

 

 

HANDLING

 

 

Precautionary Measures: 

DO NOT USE IN HIGH PRESSURE SYSTEMS in the vicinity of flames, sparks and hot surfaces. Use only in 

well ventilated areas. Keep container closed. Keep out of the reach of children.

 

General Handling Information: 

Avoid contaminating soil or releasing this material into sewage and drainage systems and bodies of 

water.

 

Static Hazard: 

Electrostatic charge may accumulate and create a hazardous condition when handling this material. To minimize this 

hazard, bonding and grounding may be necessary but may not, by themselves, be sufficient. Review all operations which have the 

potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere (including tank and container filling, splash 

filling, tank cleaning, sampling, gauging, switch loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate 

mitigating procedures.

 

 

 

DISPOSAL CONSIDERATIONS

 

 

Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or disposal. Place 

contaminated materials in containers and dispose of in a manner consistent with applicable regulations.

 

DEXRON® III OIL SAFETY DATA

 

Содержание GB703SRVTPTS

Страница 1: ...DE E MAIL US FOR A DISTRIBUTOR NEAR YOU GB703SRVTPTS ORIGINAL INSTRUCTIONS 44766 Centre Court Clinton Twp MI 48038 USA Ph 1 586 226 1500 Fax 1 586 226 1505 solutions1 gagebilt com www gagebilt com GAG...

Страница 2: ...ns 5 Safety Warnings 6 Principle of Operation 7 How to set up the GB703SRVTPTS 8 How to use the GB703SRVTPTS 9 Maintenance and Hydraulic Thread Preparation 10 Filling 11 Bleeding 12 Troubleshooting Ho...

Страница 3: ...iring or replacing defective goods or if the goods covered by this warranty are reworked or subjected to any type of additional processing This warranty is void if Seller is not notified in writing of...

Страница 4: ...held in hand weighs 1 5 lbs 68kg The entire split handle installation tool weighs 11 lbs 5 0 kg It has a 780 19 81 mm fastener setting stroke The GB703SRVTPTS split handle installation tool operates...

Страница 5: ...OF FUNCTIONS Evacuation Tube Air Hose Hydraulic Hose Actuator Vacuum Regulator Actuator Assembly Air Air Inlet Bleeder Screw Bleeder Screw Hanger Head Assembly Nose Assembly Handle Assembly Flow_Speed...

Страница 6: ...the consumable inserted tool as recommended in the instruction handbook to prevent an unnecessary increase in noise 6 If the power tool has a silencer always ensure that it is in place and in good wor...

Страница 7: ...omponents of the attached nose assembly are also moving with the piston to start the fastener installation When the fastener installation is completed the actuator assembly air is released Air pressur...

Страница 8: ...MUST read and understand all warnings and cautions WARNING It is required that eye protection hearing protection and safety boots be worn at all times while handling this equipment WARNING The users o...

Страница 9: ...actuate fastener in the air Personal injury from fastener ejecting may occur WARNING Air is exhausted from the bottom of the tool Direct bottom of the tool exhausted air away from operator other perso...

Страница 10: ...he tool several times to assure there are no leaks during use Keep hydraulic system free of dirt Proper care by operators is necessary in maintaining full productivity and reducing downtime Keep nose...

Страница 11: ...embly 704132 down on side so that the hole marked 4 on manifold handle 744303 is to the top Set head cylinder assembly 703132 over a small bucket or can Completely fill up fill bottle 745263 6 Remove...

Страница 12: ...8 Connect air supply Cycle tool ten times and check stroke of 780 19 81 mm using instructions a thru c and diagrams below We recommend using dial calipers a With the air actuator assembly 704130 relea...

Страница 13: ...sembly 704262 is recommended b Check o rings on valve sleeve 703139 valve spool assembly 703142 and valve plug 704145 If worn or damaged replace Valve sleeve removal tool 704163 is recommended 6 FASTE...

Страница 14: ...part no 402723 or other lubricant is recommended during reassembly to prevent tearing or distorting of o rings The disassembly and re assembly procedure can be accomplished by utilizing the following...

Страница 15: ...tool 3 Using a 5 8 wrench or an adjustable wrench loosen and remove the actuator assembly air 704130 from the adapter 704325 as shown above INSTALLING ACTUATOR ASSEMBLY AIR 704130 1 Apply Teflon tape...

Страница 16: ...Nm 2 Attach the seal guide 704152 to the piston rod assembly 704138 and tap the piston rod assembly 704138 through the packing plug 704118 3 Attach air piston assembly 704121 and flexlock nut 400559...

Страница 17: ...17 11 21 REV 3 23 GB703SRVTPTS INSTALLAION TOOL PARTS LIST...

Страница 18: ...18 11 21 REV 3 23 GB703SRVTPTS INSTALLAION TOOL PARTS LIST...

Страница 19: ...n this material undergoes combustion ACCIDENTAL RELEASE MEASURES Protective Measures Eliminate all sources of ignition in vicinity of spilled material Spill Management Stop the source of the release i...

Страница 20: ...BY PURCHASING 2 NOSE ASSEMBLIES WITH A 743 DESIGNATION I E 8Z 743 24VPSA MUST BE ORDERED AS COMPLETE NOSE ASSEMBLY 3 ALUMINUM RIVET STEEL MANDREL ONLY 100 PSI REQUIRED FOR ALL 1 4 STEEL RIVETS 4 1 4...

Страница 21: ...Order GB703 series installation tools fastener specific by adding the appropriate suffix see selection chart Standard SH tools are equipped with 8ft 2 4 m hydraulic hose assemblies Standard SR tools...

Страница 22: ...actual gage Alternative Styles Cont Sold Separately GB703SH Stroke 780 19 8 mm Hand held weight 2 00 lbs 9 kg Entire tool weight 7 25 lbs 3 3 kg Pull load 2 200 9 8 kN 5ftHyd Hosesarerecommendedwithus...

Страница 23: ...23 11 21 REV 3 23 GB703SRVTPTS INSTALLAION TOOL This page intentionally left blank...

Страница 24: ...ION TEFLON IS A REGISTERED TRADEMARK OF E I DUPONT DE NEMOURS CO SLIC TITE IS A REGISTERED TRADEMARK LA CO INDUSTRIES INC VIBRA TITE IS A REGISTERED TRADEMARK OF OAKLAND CORPORATION Gage Bilt offers a...

Отзывы: