Elnur
powered by Gabarrón | ECOMBI HHR | Installation Guide
11
TROUBLESHOOTING
HHR does not heat.
Please check it is connected and switched on.
Make sure the heater has not been covered or the air vent at the bottom of the
heater has not been obstructed. In these cases the safety cut-out may of tripped
and may need resetting. Please contact technical support.
HHR does not reach set up
temperature
Make sure that adequate temperature is selected. Shelves above the heater
and obstacles in front of the heater can affect the output.
Make sure the heater is sized correctly for the room.
ERR1 is displayed
Ambient temperature sensor is picking up an error. Please contact technical support.
ERR2 is displayed
Air outlet(grille) temperature sensor is picking up an error. Please contact technical
support.
ERR3 is displayed
Core temperature sensor is picking up an error. Please contact technical support.
Keyboard does not respond If display shows [- -] when pressing a key then the child lock is activated. To unlock
Press the + and - buttons (normally for about three seconds) or until [- -] disappears.
INSTALLATION INSTRUCTIONS
Factory Reset
Factory reset allows you to reset the heater back to its
factory default settings.
To Reset, turn ON the heater via the switch at the right
side of the heater while holding down the clock buttons
at the same time. Four horizontal blinking segments will
appear in the display to confirm reset complete, at this
point you can release the clock buttons.
Factory defaults:
Sun
: Comfort Temperature
:
21°C
Moon
: Economic Temperature
:
18°C
ST
: Initial % of storage charge
:
80
P01
: Start time of off peak period 1
:
00:00
P02
: End time of off peak period 1
:
07:00
P03
: Start time of off peak period 2
:
00:00
P04
: End time of off peak period 2
:
00:00
P05
: Ambient sensor -5°C
:
0.0
P06
: Max. working hours of balancing
element
:
5
P07
: Over temperature protection °C
:
2
P08
: Display temp. Centigrade or Fahrenheit :
°C
Open
: Open window detection option
:
Off
Auhr :
Automatic winter / Summer time
Weekly program resets to 00:00 - 07:00 at 18°C,
07:00 - 22:00 at 21°C, 22:00 - 24:00 at 18°C.