INSTALLATION INSTRUCTIONS
Connection and Disconnection
Each ECOHHR storage heater has its own power switch
and is located on the right side panel. The power switch
is used to turn the heater ON and OFF.
If this switch is turned OFF then the storage heater will
not take a charge when the off-peak supply is on and
will not give out any heat. Therefore, it is important to
make sure this is turned ON at all times.
Each ECOHHR storage heater requires two electrical
supplies. One is an economy tariff supply (off peak
or restricted supply) and the other is a 24hr supply
(on peak or unrestricted supply). However, the Elnur
ECOHHR is capable of utilising a single economy/24hr
supply by using the supplied link cables. Modification
to the distribution board may be required if supplied
via radial circuits.
Connection from the economy supply or economy/24hr
supply to the heater should be via a 20Amp double pole
isolator switch. (Radial circuits)
Connection from the 24hr supply (on peak or unrestricted
supply) to the heater should be via a fused double pole
isolator switch or a fused RCD isolator switch, depending
on the installation.
Note
This heater can be connected to the standard two
electrical supplies Economy and 24hr supply or one
single Economy/24hr supply.
User Control Panel
You will find the keypad on the top right side on the
heater. This easy to use keypad only has four buttons,
however these four buttons can be used in different
ways to give you many functions and will be explained
in more detail in later sections.
Basic Key functions:
This button is used to set the
‘Comfort’ temperature. Default is 21°C.
This button is used to set the
‘Economy’ temperature. Default is 18°C.
This button is used to decrease values.
This button is used to increase values.
Pressing these buttons together will
allow you to set the Day and Time.
Pressing these buttons together
will allow you to set the weekly program.
&
&