RELOCATION
If during reinstallation the thermal insulation shows any sign of damage, it must be removed and replaced by an
identical part.
WARNING: Relocation to another location must be carried out by an experienced
technician.
!
MANUALLY RESET TEMPERATURE LIMITER
This heater employs a manual reset temperature limiter (see LR in the connection diagram).
This safety device operates when high temperatures are reached at the top of the heater. It requires re-setting
manually: Let the heater cool. The cause of overheating should be investigated.
MANUALLY RESET TEMPERATURE LIMITER
!
WARNING: Re-setting manually must be carried out only by an experienced technician.
Turn off the heater at the circuit breaker.
Take off the front panel by removing the two screws located at the bottom. Find the limiter LR in the connection
diagram and push the small pin until a click is heard.
MAIN COMPONENTS LIST
Storage Heating Element
Ref. 10190410
275W Balancing Element (ECOHHR20)
Ref. 15192000
410W Balancing Element (ECOHHR30)
Ref. 15192002
550W Balancing Element (ECOHHR40)
Ref. 15192004
110ºC Left Limiter
Ref. 15190725
140ºC Right Limiter
Ref. 15190720
140ºC Storage Limiter
Ref. 15190720
160ºC Cut Out Manual Limiter
Ref. 15190730
Switch
Ref. 46100530
Main PCB
Ref. 15192125
Keyboard PCB
Ref. 15190060
Core Sensor
Ref. 15192140
Air Sensor
Ref. 15192145
Room Sensor
Ref. 60100580
Fan (ECOHHR20)
Ref. 15192636
Fan (ECOHHR30 & ECOHHR40)
Ref. 15192638