background image

Elnur

 

powered by Gabarrón  |  ECOMBI HHR  |   Installation Guide

4

INSTALLATION INSTRUCTIONS

In order to achieve a correct installation of this device, follow these steps

1. 

Choose the right location to install the Ecombi HHR. The minimum clearances must be respected from the  

 

appliance to any combustible material such as furniture or curtains. To reduce the risk of fire, do not store  

 

or use petals or other flammable liquids and vapours in the vicinity of the heater.

2. 

Open the heater box at the indicated side and install the supporting feet without removing the heater.

3. 

 Flip the box upside down to allow the heater  

to stand on its feet and remove the carton.  

Please check that it is the correct model and  

is in good condition.

Check that all parts have been delivered and are 

intact: 

 

-  1 ECOMBIHHR heater casing.

 

-  1 Bag containing 2 screws, 2 rawl plugs,  

 

 

4 white screws and 2 black female spade  

 

 

connector wires.

 

-  2 supporting feet.

 

-  1 top fixing plate.

 

-  2 side fixing plates.

 

-  This Guide

 

The casing and storage bricks are supplied  

 

separately. Check the supplied brick  

 

 

packages correspond to the ones indicated  

 

on the heater carton.

 

The heater operation is not affected if bricks  

 

with minor damage are used.

4.   Screw the top fixing plate to the wall, making the  

 

two required points to drill at the recommended  

 

distance depending on the model. Use the rawl  

 

plugs and screws contained in the plastic bag  

 

to fix the fitting to the wall.

!

!

Содержание Elnur ECOMBI HHR Series

Страница 1: ...ore installing or using this appliance for the first time Please read these instructions carefully before installing or using this appliance for the first time Installation Instructions ECOMBI HHR Hig...

Страница 2: ...n or approved service agent before reusing Do not use the heater outdoors To disconnect the heater turn off the isolator switches and at the consumer unit Do not insert or allow foreign objects to ent...

Страница 3: ...t must be replaced This heater should be switched off at the isolation switch and or circuit breaker before any repair work is carried out on the heater This appliance is only intended for a fixed ins...

Страница 4: ...heater to stand on its feet and remove the carton Please check that it is the correct model and is in good condition Check that all parts have been delivered and are intact 1 ECOMBIHHR heater casing 1...

Страница 5: ...ppliances are heavy it is the installers responsibility to ensure the correct installation and wall support of these devices to prevent them from overturning 6 Take off the front outlet grill by remov...

Страница 6: ...ft and tilt the elements outwards being careful not to damage the insulation on the bottom of the heater and carefully place the storage bricks Arrange two levels of bricks with the flat side facing t...

Страница 7: ...tly you will have no difficulty in refitting the panel Make sure the bottom edge of the inner panel is inside the front lip of the heater Please see below 14 Replace the front panel When refitting the...

Страница 8: ...E POWER SUPPLY CONNECTION The Elnur ECOHHR is capable of utilising a single economy 24hr supply by using the supplied link cables 1 Use the 2 black link cables provided in the plastic bag to jumper th...

Страница 9: ...omy supply or economy 24hr supply to the heater should be via a 20Amp double pole isolator switch Radial circuits Connection from the 24hr supply on peak or unrestricted supply to the heater should be...

Страница 10: ...ed at this point you can release the moon button Use the and buttons to move down and up the menu options To look or change each setting press and release the moon button and then use the and buttons...

Страница 11: ...y shows when pressing a key then the child lock is activated To unlock Press the and buttons normally for about three seconds or until disappears INSTALLATION INSTRUCTIONS Factory Reset Factory reset...

Страница 12: ...WARNING Re setting manually must be carried out only by an experienced technician Turn off the heater at the circuit breaker Take off the front panel by removing the two screws located at the bottom...

Страница 13: ...f 15192636 3 275W Balancing Element ECOHHR20 Ref 15192000 4 160 C Cut Out Manual Limiter Ref 15190730 5 110 C Left Limiter Ref 15190725 6 140 C Right Limiter Ref 15190720 7 140 C Storage Limiter Ref 1...

Страница 14: ...f 15192638 3 410W Balancing Element ECOHHR30 Ref 15192002 4 160 C Cut Out Manual Limiter Ref 15190730 5 110 C Left Limiter Ref 15190725 6 140 C Right Limiter Ref 15190720 7 140 C Storage Limiter Ref 1...

Страница 15: ...f 15192638 3 550W Balancing Element ECOHHR40 Ref 15192004 4 160 C Cut Out Manual Limiter Ref 15190730 5 110 C Left Limiter Ref 15190725 6 140 C Right Limiter Ref 15190720 7 140 C Storage Limiter Ref 1...

Страница 16: ...0 0005 0 0005 0 0005 kW MODEL S GABARRON ECOHHR20 ECOHHR30 ECOHHR40 ErP Item Value All models Type of heat input Electronic heat charge control with room and or outdoor temperature feedback Yes Type o...

Страница 17: ...ay not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of...

Отзывы: