background image

Quick Reference

Factory Reset

To set the unit back to factory settings you will need to send a text message

#

RESET

#

Please Note 

- doing this will reset ALL of your parameters. Only send a reset command

when necessary.

The 

GREEN 

ready LED will flash eight times.

Dipswitch Settings

Dipswitch 1 = 

ON = Siren ON

OFF = Siren OFF

Dipswitch 2 = 

ON = 3G

OFF = 2G

For more technical support please browse the FAQ’s on our website

 www.gsm-

activate.co.uk

Alternatively email our technical support team at

 [email protected]

 and we will

do our best to respond to your querry within 24 hours Monday- Friday.

06/10/21 - GD 

Page 8

Содержание e-CO Series

Страница 1: ...Page 1 MODEL ECO DOOR V2 GSM 2G 3G Door Contact Alarm e CO RANGE ...

Страница 2: ...dule Specification GSM Frequency Quadband Freq 850 900 1800 1900 3G Model 2100 Mhz Power Supply Voltage 9 24 Volts DC 1 Amp Min Current Used in Standby Mode 60mA Max IP65 Rated Enclosure for Outside Installation Micro 2G or 3G Simcard No Landline Required Dimensions L100 x W68 x H50mm Dimensions PCB Only L95 x W67mm Sim Active Function Operating Temperature 10 40 C Programmed by Text Message Text ...

Страница 3: ...detector is receiving by texting the command SIGNAL The detector will perform a test on the signal strength You will receive a text confirming the signal strength between 0 up to 30 We strongly recommend that you place the unit where it can receive a signal of at lease 10 Anything less than this will make the unit unreliable SIM Active Function Our GSM Auto Dialler comes with a SIM Active function...

Страница 4: ...le has a signal and the unit is ready for use Please Note To avoid confusion we have colour coded the hash and the equals symbols Furthermore where it indicates a phone number this should be your number or the numbers you wish the unit to contact Example hash 1 2 or 3 equals phone number hash To programme mobile numbers into the unit you will need to send them as a text to the unit as follows 1 07...

Страница 5: ...the 2G 3G Door Contact Alarm Once you have positioned the door contact installed the simcard and programmed the numbers the system is ready to use The GSM Door Contact Alarm has two modes alarm mode and auto mode Alarm mode you have to arm the alarm manually each time when required via a text message command or via the keyfob provided Auto mode the alarm is always armed You should choose which mod...

Страница 6: ...e text command above or by using the fey fob In auto mode the key fob and text message are disabled the alarm is always Active After the alarm is triggered it will automatically reset to active after 20 seconds In the event of a power loss the unit will remember if it was armed when power is restored How to use the Relay Output The relay has been programmed to trigger the siren for 60 seconds in t...

Страница 7: ...n the dialler 1 Hold down the pairing button on the RF Module for 3 seconds refer to figure 1 2 Trigger the door switch 3 The RF module has a RED LED which will flash when pairing in complete Figure 1 Pairing the Wireless Door Sensors www gsm activate co uk 01273462380 sales gsm activate co uk ...

Страница 8: ... necessary The GREEN ready LED will flash eight times Dipswitch Settings Dipswitch 1 ON Siren ON OFF Siren OFF Dipswitch 2 ON 3G OFF 2G For more technical support please browse the FAQ s on our website www gsm activate co uk Alternatively email our technical support team at technical gsm activate co uk and we will do our best to respond to your querry within 24 hours Monday Friday 06 10 21 GD Page...

Отзывы: