4

. OPERATION PANEL 

 

5

. DIMENSIONAL DRAWINGS 

 

 

Содержание ARCH 90 90X3W

Страница 1: ...1 ...

Страница 2: ... condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your fixture for damage and be sure all accessories necessary to operate the fixture have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Inside the box you sho...

Страница 3: ...system which connected ground enough The projector s ground cable should be connected with the ground cable of the power supply system as well The ground mark of the light metal cover should be connecting with the installation bricked steadily 4 Connecting the main power supply should be done by the professional person 5 Please check the voltage frequency data of power supply system is suitable fo...

Страница 4: ...203 x 335 4 mm Lens angle standard 45º 15º 30º 60º are selective It adopt the LCD display as its operating in terrace very easy for using on the floor or hang on With inner automatic run function master slave setting very easy to operate by users The fixture s out shape adopt pressed construction design and strong wind refrigeration system which be know as a good cooling system DMX channel Six and...

Страница 5: ...4 OPERATION PANEL 5 DIMENSIONAL DRAWINGS 5 ...

Страница 6: ...6 PHOTOMETRIC DATA 6 ...

Страница 7: ...the installation area can hold a minimum point load of 10 times the device s weight Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable To avoid injury never stand directly below the device when mounting removing or servicing the fixture Mounting points This fixture can be placed on a flat level surface Be sure this fixture is kept at ...

Страница 8: ... input and connect the second projector s output to the third projector s input And in the same way for the rest eventually connect the last projector s output all the projectors are together as the following figure The projectors control signal output or input by using the 3 pin XLR pug and socket If need to long then the communication cable please make sure the both side of 3 pin plug is one to ...

Страница 9: ... the output socket on the last projector in the chain Refer to the connection as above Picture We suggest using the DMX signal distributor when the distance of the lights over 15meter In case of effect the light communication because of the signal feeble 3 Light power connection After doing the above operation and making sure all the projectors had been installed with natural operate press the pow...

Страница 10: ... that the Lighting equipment is switched on 2 Power the display window flashes the bottom right corner of the small dots indicating that the lamp is switched on DMX512 signal control status is pending 3 Key in the absence of any action the display menu will automatically turn off after 15 seconds 10 ...

Страница 11: ...fect 6 1 RED 0 no light 1 255 by dark to 100 light 2 GREEN 0 no light 1 255 by dark to 100 light 3 BLUE 0 no light 1 255 by dark to 100 light 4 WHITE 0 no light 1 255 by dark to 100 light 5 AMBER 0 no light 1 255 by dark to 100 light 6 DIMMER 0 255 By dark to light dimmer ...

Страница 12: ... 255 by dark to 100 light 5 AMBER 0 no light 1 255 by dark to 100 light 6 DIMMER 0 255 By dark to light dimmer 7 SHUTTER 0 3 No shutter 4 83 fast light slow destroy 84 163 slow light fast destroy 164 255 by slow to fast shutter 8 MACRO 0 3 No 4 255 by slow to fast Note In accordance with 1 5 channel phase DMX value size order successively bright Note The console is closed lights turned off before ...

Страница 13: ...11 CIRCUIT CONNECTING DIAGRAM 13 ...

Страница 14: ...12 EXPLODE DIAGRAM AND LIST 14 ...

Страница 15: ...M0600825 15 Z0600742 3 M0300772 16 M0600930 4 M0101994 17 M0101978 5 M0202175 18 M0300774 6 M0400149 19 M0300773 7 M0101975 20 M1000908 8 M0101976 21 M01019106 9 Z0600176 22 M1300768 10 M0400151 23 Z0600325 11 M1300767 24 M0300768 12 M0101965 25 M0101979 13 M01019107 ...

Страница 16: ...he start code address and the function option are correct 2 Please check whether the communicate control cable is on good connection or the cable is too long or interrupt 3 Please check the control system is not valid check the signal amplifier of chain connected is valid 4 Please check whether the communicate cable is too long or the other equipment is mutually conjugate 5 Please arrange the wire...

Страница 17: ...age of the lamp Please use the alternative operation to solve this problem 3 Please disconnect the power supply when begin to maintenance take down the light Please let the parts cool down 10 minute at least then begin to install 4 Please inspect the lens or other moving parts timing and keep them clear and static If find anything damaged or looseness must change a lamp or fix the lamp in order to...