G-Lab GSC-4 Скачать руководство пользователя страница 3

Important safety instructions

– 

Read these instructions and follow them.

– 

Prevent this device against moisture or spilling liquid inside.

– 

Clean only with dry cloth.

– 

Do  not  install  near  any  heat  sources  such  as  radiators,  heat  registers,  stoves,  or  other  apparatus                        

producing a lot of heat
– 

Protect the power supply cord from being walked on or pinched.

– 

Only use attachments/accessories specified by the manufacturer.

– 

Unplug this device during lighting storms or when unused for long periods of time.

– 

Do no open device or its power supply casing.

– 

The power supply adapter should be installed in the socket outlet and disconnection of the adapter should 

be easily accessible.
– 

To completely disconnect from AC mains disconnect the power supply adapter from the AC receptacle.

FCC Compliance

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this 
device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in 
a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio communications. However, 
there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures:

– 

Reorient or relocate the receiving antenna.

– 

Increase the separation between the equipment and receiver.

– 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

– 

Consult the dealer for help.

Declaration of Conformity

Elzab Soft sp. z o.o., ul. Kruczkowskiego 39, 41-813 Zabrze, Poland, 
declare under sole responsibility, that the following product:

G LAB/GSC 4 Guitar System Controller

conforms with requirements of the EC Council Directives:

• 

2006/95/EEC Low Voltage Directive,

• 

2004/108/EEC Electromagnetic Compatibility,and holds CE mark. Above named product conforms with the following 

standards:

• 

PN-EN 60065:2004 /EN 60065:2002/ Audio, video and similar apparatus - Safety requirements.

• 

PN-EN 55103-1:2000 /EN 55103-1:1996/ Electromagnetic compatibility - Product family standard for audio, video, audio-

visual and entertainment lighting control apparatus for professional use - Part 1: Emission 

• 

PN-EN 55103-2:2001 /EN 55103-2:1996/ Electromagnetic compatibility - Product family standard for audio, video, audio-

visual and entertainment lighting control apparatus for professional use - Part 2: Immunity

Arkadiusz Kocik

President of the Elzab Soft sp. z o.o. Board of Directors

Copy of original EC declaration of conformity is available for download on our website 

http://www.glab.com.pl

Содержание GSC-4

Страница 1: ...instrukcja obs ugi bedienungsanleitung mode d emploi user manual GUITAR SYSTEM CONTROLLER...

Страница 2: ...TCH outs 18 3 5 3 MIDI 18 4 PROGRAMMING MODE 19 4 1 Preset and MFS basic programming 20 4 1 2 Bank name 22 4 1 3 MFS name 22 4 1 4 LOOP section 22 4 1 5 SWITCH section 22 4 2 Settings programming 22 4...

Страница 3: ...nce to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television recepti...

Страница 4: ...very high impedance circuit no tone coloration on guitar signal LOOP SPLIT mode that enables the connection of two stomp boxes at the amp s front input and three in the amp s FX loop without a ground...

Страница 5: ......

Страница 6: ...user manual GSC_4 5 1 OVERVIEW...

Страница 7: ...t connect to effect input 6 EFFECT LOOP RETURN input connect from effect output 7 TFT Display 8 GSC 4 programming keyboard 9 MAIN OUT signal output 10 TUNER output 11 MAIN IN signal input 12 PRESET BA...

Страница 8: ...user manual GSC_4 7 1 2 Keyboard description and layout 1_ ESC key 2_ ARROW UP key 3_ MENU key 4_ ARROW LEFT key 5_ OK key 6_ ARROW RIGHT key 7_ ARROW DOWN key...

Страница 9: ......

Страница 10: ...user manual GSC_4 9 2 BASIC OPERATION...

Страница 11: ...ber 3 MFS type 4 Bank name 5 Selected MFS name 6 LOOP section with LOOPS and BUFFER indicators 7 SWITCH section with relays indicators 8 MIDI section with indicators for all 10 MIDI devices 9 LOOP SPL...

Страница 12: ...user manual GSC_4 11 Figure 2 1 1 Preset MFS mode Figure 2 1 2 Loop Modifier MFS mode Figure 2 1 3 Switch Modifier MFS mode Figure 2 1 4 Midi Modifier MFS mode...

Страница 13: ...w is displayed in the SETTINGS PROGRAMMING It is built almost always in the same way The only difference refers to the functions name and the field s quantity including their designations Use the keyb...

Страница 14: ...cted text for editing At this instance there are few options Press OK to keep the text and move the cursor to the end of the text Press LEFT and RIGHT ARROWS to keep the text and move the cursor to th...

Страница 15: ...ues is on the top left side No 1 in Figure 2 05 The INACTIVE field is the first active field after the screen is displayed At this instance there are few options Press OK to set the value to INACTIVE...

Страница 16: ...user manual GSC_4 15 3 WORKING MODE...

Страница 17: ...to the following mechanisms BANK color back round is always the same MFS number function and name are changing color back round depending on MFS function see figures 2 1 1 2 1 2 2 1 3 2 1 4 Fields an...

Страница 18: ...y field with gray color 5 6 7 8 9 10 indicates that there is no defined MIDI device 3 3 Recalling the preset Press the MFS footswitch from 0 to 9 to recall the preset Controller will recall all preset...

Страница 19: ...e the relays to switch Relays will not switch when a recalled preset or MFS doesn t change the LOOP S state In the first stage the signal is muted Then relays are switched and muting is off Recalling...

Страница 20: ...user manual GSC_4 19 4 PROGRAMMING MODE...

Страница 21: ...mode of the switch Fields 4 and 5 mean that switches are INACTIVE Select and recall the Bank and MFS footswitch to enter its programming For basic preset programming press OK Use the keyboard ARROWS...

Страница 22: ...ctive for which MFS mode PRESET ON the section s field is set to on and causes the immediate reaction of hardware OFF the section s field is set to off and causes the immediate reaction of hardware PC...

Страница 23: ...r 2 2 it is described how to move in the MENU setting Warning IF THE SETTINGS PROGRAMMING WAS ACTIVATED FROM THE MODIFIER THEN THE QUIT WILL RECALL THE NEAREST PRESET PRESET ON the section s field is...

Страница 24: ...o assign up to a maximum of 20 such functions for each midi device To set the controller list proceed as follows MENU MIDI DEVICES MIDI DEVICE NAME CONTROLLER LIST Beside the controller s number it is...

Страница 25: ...sending commands 4ms 8ms 16ms 32ms 64ms CURRENT VALUE currently sent value CALIBRATION pedal s calibration CHARACTERISTIC of pedal s response Typical expression pedals feature a linear characteristic...

Страница 26: ...of signal in proportion to the full signal range Controller enables to receive PROG CHANGE and CONTROL CHANGE commands from an external MIDI device for remote control Commands enable to remotely recal...

Страница 27: ...the loop 3 will permanently switch ON The information on the main display will turn to SPLIT WILL CHANGE Then switch off the controller After reconnecting the power of the controller loops will split...

Страница 28: ...user manual GSC_4 27 5 CONNECTING GSC 4 ACCESSORY...

Страница 29: ...adapter is required Many amps are equipped with a female Jack footswitch input If your amp is equipped with such type of connector please check on www glab com pl or ask your dealer and amp manufactur...

Страница 30: ...AH PAD input The wah pad is a touch sensor enabling to switch automatically on off state of the wah wah or the WHAMMY effect without the effect switcher The WAH PAD can also be used for a typical anal...

Страница 31: ...ectronic equipment Parties collecting such equipment organise a system including local collection points shops and other units allowing to return such equipment This Directive assures an user free of...

Страница 32: ......

Страница 33: ......

Страница 34: ...Company address Elzab Soft sp z o o ul Kruczkowskiego 39 41 813 Zabrze Poland phone 48 32 370 63 08 Sales Export Department e mail glab glab com pl phone 48 32 370 63 08 Technical Support e mail help...

Отзывы: