background image

 3 

SL DC2 GATE MOTOR 

INSTALLATION AND SET UP 

INSTRUCTIONS 

 

Motor cover 

Solar Regulator (Only 
installed in solar 
powered gate 
motors) 

Drive Gear 

Limit 
Switch 
Spring  

Circuit Board 

Manual release 
mechanism 

Limit Switch 
Assembly 

Remote Receiver 

Battery 

Motor 

Gate motor mounting foot 

© 2012 G Force Automatic Gates All Rights Reserved 

Содержание SL 2000 DC2

Страница 1: ...wered and 12V Low Voltage Installation and Set Up Instructions Unit 27 49 Corporate Boulevard Bayswater Vic 3153 Phone 1800 111 930 Email info gforceautogates com au Web www gforceautogates com au 201...

Страница 2: ...e the gate can close without hitting any obstructions or suitable safety accessories are also installed This equipment is designed for use as a Sliding Gate Opening Device only Do not attempt to use f...

Страница 3: ...cover Solar Regulator Only installed in solar powered gate motors Drive Gear Limit Switch Spring Circuit Board Manual release mechanism Limit Switch Assembly Remote Receiver Battery Motor Gate motor...

Страница 4: ...ush Button Trigger Terminals Connect wires to OSC and COM PE Beam Terminals Connect wires to PEB and COM Power Out Connection Terminals V positive terminal 0V Negative terminal Motor Force Trim Pot PE...

Страница 5: ...direction until you can freely move the motor drive gear and or gate freely by hand Automatic Mode Insert the key in the keyhole and turn the key in the Open direction as shown by the arrow on the co...

Страница 6: ...rd should now be powered and great care should be taken to avoid shorting out or otherwise damaging the circuit board Green and Red gate direction LED s will flash when power is connected Activate the...

Страница 7: ...locate the M1 Motor terminals on the circuit board Swap the red and black motor wires connected to M1 Motor terminals on the circuit board The red wire should be connected to the terminal that had th...

Страница 8: ...he drive gear We suggest a gap of 2 3mm between rack and drive gear Temporarily placing a 2 3 mm spacer under the motor feet can help set the required height Remove the spacer when finished To ensure...

Страница 9: ...tions when the gate motor is operating the limit switch brackets should push against the limit switch spring to click the limit switch off an audible sound can be heard when the switching occurs Put t...

Страница 10: ...orque force to fully open and close the gate However the more torque the motor has the less obstruction sensitivity there is and therefore the gate may hit an obstruc tion more forcefully Usually the...

Страница 11: ...Once time is set flick DIP switch 1 back to OFF To start the Auto Close function flick DIP switch 8 to ON and leave it on To disable the Auto Close flick DIP switch 8 back to OFF To adjust the Auto C...

Страница 12: ...Cable RED active WHITE neutral Terminal Block Solar Panel Wires RED wire to RED Positive wire BLACK wire to NEGATIVE wire Weather Proof Enclosure Terminal Block Solar Panel Wires POSITIVE wire to gre...

Страница 13: ...ative wire to Black battery terminal Terminal Block 12 v Low Voltage Transformer Wires 1 5mm Twin Active Low Voltage Cable Weather Proof Enclosure If the 12 v low voltage transformer wires need to be...

Страница 14: ...ranted including but not limited to damages for lost services cost of substitute services lost profits expenses arising out of third party claims or personal injury G Force s maximum liability under a...

Страница 15: ...cables are not frayed at the ends 5 Ensure Receiver is firmly mounted 6 Tighten all mounting and attachment bolts 7 Check screws on Push Button covers are intact and tight 8 If Photocells Sensors are...