Operators and Technicians Manual
2011 – 2014 FutureLogic, Incorporated. All Rights Reserved.
MNL Page 18 04/10/2014
MNL-000067 REV.X03
Set the Printer Communication
Note:
Perform this procedure with the unit powered on.
1.
Press the Lid Release Lever to open the Lid.
2.
Slide and release the COMM Switch to Position 1. The Red LED flashes. The selection is now Port 1.
3.
(Optional) To step to Port 2, slide the COMM Switch again to Position 1.
4.
Slide or hold the COMM Switch to step through the port selection options.
Position 1
Setting
LEDs
Parameter
Notes
Green
Yellow
Orange
Red
1
0
OFF
OFF
OFF
*Flashing*
Port 1
Main
1
ON
OFF
OFF
*Flashing*
Port 2
Secondary
2
OFF
ON
OFF
*Flashing*
Port 0
Debug
3
ON
ON
OFF
*Flashing*
Not Used
Not Used
4
OFF
OFF
ON
*Flashing*
Not Used
Not Used
5
ON
OFF
ON
*Flashing*
Not Used
Not Used
6
OFF
ON
ON
*Flashing*
Not Used
Not Used
7
ON
ON
ON
*Flashing*
Not Used
Not Used
Table Note:
1
The red LED indicating the settings selection mode blinks at a rate of 200 ms.
5.
Slide the Comm Switch to Position 2.
The Red LED stops flashing; all LEDs are off. The selection is now 9600 Baud, Xon Handshaking.
6.
To select other baud rate and handshaking parameters, slide or hold the COMM Switch in Position 2 to
step and cycle through the table below.
Position 2
Setting
LEDs
Baud Rate
Handshake
Green
Yellow
Orange
Red
1
OFF
OFF
OFF
OFF
9600
XON (SW)
2
ON
OFF
OFF
OFF
9600
RTS (HW)
3
OFF
ON
OFF
OFF
38400
XON (SW)
4
ON
ON
OFF
OFF
38400
RTS (HW)
5
OFF
OFF
ON
OFF
115200
XON (SW)
6
ON
OFF
ON
OFF
115200
RTS (HW)
7
OFF
ON
ON
OFF
19200
XON (SW)
8
ON
ON
ON
OFF
19200
RTS (HW)
9
OFF
OFF
OFF
ON
57600
XON (SW)
10
ON
OFF
OFF
ON
57600
RTS (HW)
11
OFF
ON
OFF
ON
230400
XON (SW)
12
ON
ON
OFF
ON
230400
RTS (HW)
13
OFF
OFF
ON
ON
460800
XON (SW)
14
ON
OFF
ON
ON
460800
RTS (HW)
15
OFF
ON
ON
ON
921600
XON (SW)
16
ON
ON
ON
ON
921600
RTS (HW)