7. Registers
All settings of the FDP02 are stored in its registers.
7.1. List of Registers
Below table shows list of all registers.
Register Function
Default
Setting range
Remarks
REG00 Local station address
00H
00H to EFH
000 to 239
REG01 Group address
F0H
F0H to FEH
240 to 254
REG02 Destination address of
Headerless-packet
00H
00H to FFH
000 to 255 (to be used for headerless packet
transmission)
REG03 Transmission mode
F0H
F0H, FFH
Default: Packet transmission mode
REG04 ID code 1
00H
00H to FFH
REG05 ID code 2
00H
00H to FFH
REG06 Frequency group
03H
01H to 03H
Default: 3-band mode
REG07 Frequency 1
02H
02H to 51H
Default: 2,402 MHz
REG08 Frequency 2
2AH
02H to 51H
Default: 2,442 MHz
REG09 Frequency 3
51H
02H to 51H
Default: 2,481 MHz
REG10 Unused
01H
-
REG11 Retransmission
frequency
0AH
00H to FFH
Default: 10 times
REG12 Unused
00H
-
REG13
Serial response of sent data
00H
00H to 07H
Default: "Returning P0 and P1 responses,"
"Enabling N0 response," and "Enabling
response"
REG14 Unused
00H
-
REG15 Command recognition interval
00H
00H to FFH
Default: 0 ms (to be used for headerless
packet transmission)
REG16 Unused
00H
-
REG17 Buffer clear
64H
01H to FFH
Default: 10s
REG18 Address check
8DH 8CH,
8DH
Default: "Enabling destination address
check at reception"
REG19 Unused
00H
-
REG20 Wired-communication setting 1
(serial communication)
00H
00H to FFH
Default: 9,600 bps, 8 data bits, no parity,
and 1 stop bit
REG21
Wired-communication setting 2
(flow control),
Low power stand-by mode,
Extended stand-by time
09H
00H to FFH
Default: "Disabling hardware flow control"
W
ithout low power stand-by mode
Extended stand-by time is Zero
REG22 Low power stand-by time
04H
01H to FFH-
Default: 40ms
REG23
Wired-communication setting 3
00H 00H,10H
Default: "Not adding '<Cr><Lf>' to received
data" (to be used for headerless packet
transmission)
REG24
Delimiter for headerless-packet
transmission
Unit of sleep time duration
C1H
80Hto 83H
C0H to C4H
Default: <Cr><Lf> (to be used for
headerless packet transmission)
x 10ms
REG25 Sleep time
04H
01H to FFH
Default: 40ms
REG26 Time-out of headerless-packet
data input
01H
01H to FFH
Default: 10 ms (to be used for headerless
packet transmission)
* To initialize the registers, use the INI command (see Section 8.3.3) or input an initialization signal from the
/INI pin (see Section 9.1).