41
<
Basic Operation
>
Model ID
FASSTest, T-FHSS
For the sake of safety, this function does not operate the receiver if the model data of the model program settings that
does not match the aircraft is used by mistake.
■ In the system types (FASSTest, T-FHSS) compatible with the model
ID function, a unique ID number (model ID) is set to each model
data. Linking with a receiver stores the model ID of the model data
in that receiver. The receiver operates only when it receives radio
waves transmitted using model data that matches the stored model
ID. As a result, the receiver does not operate even if model data of an
unintended setting is used by mistake, so it is possible to prevent a
malfunction due to a model selection mistake.
Link is required when a new model is made from a model selection.
Model 1 Receiver
Add new model data
Link
Select a model in Model Select. Link with a receiver that matches the model.
Link
Link
Model 2 Receiver
Model 3 Receiver
1:
3:
Model 1
Model 2
Model 3
2:
1:
3:
Model 1
Model 2
Model 3
2:
1:
3:
Model 1
Model 2
Model 3
2:
1:
3:
Rx 1
Rx 2
Rx 3
Model 1
Model 2
Model 3
2:
Select Model 2
It works with different model data.
There is a risk of flying with different model data !
Select Model 2
Model 2 only works with Model 2 data.
There is no risk of flying with different model data.
Conventional system
Model ID
Operation
Operation
Rx 1
Rx 2
Rx 3
Operation
Operation
1:
3:
Model 1
Model 2
Model 3
2:
Not Operation
Not Operation
When using R3004SB
■
When using the
R3004SB
, set “Receiver” in the system type screen T-FHSS mode setting to
[R3004SB]
.
When using other T-FHSS compatible receivers, set "Receiver" to [Normal].
R3004SB receiver does not
support model ID function.
Change to "R3004SB"
■ If you want to use different model data from the model data that you
have been using, link again.
■ Model ID feature is enabled only if the system type is FASSTest or
T-FHSS. Please note that model ID function can not be used on other
systems.
■ For safety reasons, model ID function can not be disabled.
■ Model data that can be stored in internal memory is up to 250
models.
■ Model ID is automatically set when copying or adding model data.