background image

 

 

 

18 

Warranty 

Installation, Operation and Maintenance Manual 

Oxi-Gen Oxi-2P,3P,4P, 5P & 6P System 

 

 

 
For  the  lifetime  of  the  original  purchaser,  at  the  original  residential 
place of installation of this 

OxiGen 

Water Treatment System, 

US WA-

TER SYSTEMS, INC.

  warrants the following: 

 

LIFETIME COVERAGE 

 

Media Tank(s) 

Hydrogen Peroxide Solution Tank 

 

Free  of  all  costs  to  you  except transportation  and  labor  charges, we 
warrant that we will replace or repair the fiberglass media and hydro-
gen peroxide storage tank, if for any reason it is found to be defective, 
because of faulty materials or workmanship. 

 

FIVE YEAR COVERAGE 

 

Electronics 

Drive Motor 

We warrant that for five (5) years from the date of installation, we will 
replace the Backwashing Filter Valve and Electronics free of charge to 
you except for transportation and standard labor charges. 

 

 

TWO YEAR COVERAGE 

 

STENNER

 PUMP 

Catalytic Media 

We warrant that for two (2) years from the date of installation, we will 
replace the 

STENNER

 Pump & Catalytic Media free of charge to you 

except for transportation and standard labor charges. 

 

 

GENERAL PROVISIONS 

This warranty does not apply to any commercial or industrial installa-
tions or to any part of the water conditioner which has been subjected 
to misuse, neglect, alteration or accident; or  to any damage caused 
by  fire,  flood,  freezing,  Acts  of  God,  or  any  other  casualty,  or  if  the 
original  serial  numbers  have  been  removed.    Fouling  or  damage  to 
the resin caused by iron, sulfur, bacterial iron, silt, sand, tannins, or-
ganics, bacteria, hot water or chlorine voids the warranty on resin.  
 

 
 
 
 
 
These warranties are in lieu of all other warranties expressed  
or  implied, and we do not authorize any person to assume for us any 
other obligation on the sale of this water conditioner

.  

No responsibil-

ity is assumed for delays or failure

 

to meet these warranties caused 

by strike, government regulations or other circumstances beyond the 
control of 

US WATER SYSTEMS, INC.

 

T

O

 

OBTAIN

 

WARRANTY

 

SERVICE

CALL

 

OR

 

WRITE

:   

US  WATER  SYS-

TEMS,  INC.    1209  C

OUNTRY

  C

LUB

  R

OAD

    I

NDIANAPOLIS

,  IN    46234 

(317) 271

-

8600.

 

 
ANY IMPLIED WARRANTIES OF FITNESS OR MERCHANTABILITY 
ARE LIMITED TO THE TERMS OF THIS EXPRESSED WARRANTY 
AND  THERE  ARE  NO  WARRANTIES  WHICH  EXTEND  BEYOND

 

THOSE  HEREIN.  

US WATER

   SHALL  NOT  BE  LIABLE  FOR  ANY 

INCIDENTIAL OR CONSEQUENTIAL DAMAGES. 
 
SOME  STATES  DO  NOT  ALLOW  THE  EXCLUSION  OR  LIMITA-
TIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE 
ABOVE LIMITATION MAY NOT APPLY TO YOU.  THIS WARRANTY 
GIVES  YOU  SPECIFIC  LEGAL  RIGHTS,  AND  YOU  MAY  ALSO 
HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. 
 
THIS  WARRANTY  MAY  BE  TRANSFRRED  TO  A  SUBSEQUENT 
OWNER  WITH  WRITTEN  APPROVAL  OF 

US  WATER

  AND  PAY-

MENT OF STANDARD TRANSFER FEE. 
 

FOR YOUR RECORDS: 

Model  _________________________________________

 

 
 

Serial __________________________________________ 

Date Installed ___________________________________ 

 

 

 

Oxi-Gen 

Limited Lifetime Warranty

 

Содержание Oxi-Gen 150-OXi-2P

Страница 1: ...on Sulfur and Manganese Eradication System Oxi Gen 150 OXi 2P Oxi Gen 150 OXi 3P Oxi Gen 150 OXi 4P Oxi Gen 150 OXi 5P Oxi Gen 150 OXi 6P US Water Systems Inc 1209 Country Club Road Indianapolis IN 46...

Страница 2: ...and Valve Installation 8 Carbon Filter Installation Instructions 9 Carbon Filter Valve Features 10 Carbon Filter Valve Features and Programming 12 Carbon Filter Valve Programming 13 Carbon Filter Sta...

Страница 3: ...er of bathrooms 1 Bathroom 5 GPM 2 Bathrooms 8 GPM 3 Bathrooms 10 GPM 4 Bathrooms 12 GPM 5 Bathrooms 15 GPM 6 Bathrooms 20 GPM Hydrogen peroxide or H2O2 is a powerful yet versatile oxidant that is bot...

Страница 4: ...e oxidizes the contaminants and the by product is H2O water This is much safer than using chlorine in that chlorine can cause other problems in the water stream such as chloramines and trihalomethanes...

Страница 5: ...to assure the accuracy of the dosage The Stenner Proportional Injection System can be utilized to inject any number of chemicals including chlorine hydrogen peroxide polyphosphate Rid O Rust and many...

Страница 6: ...5 Secure wall mount bracket to wall studs using the included lag bolts or other suitable hardware Hang panel on to wall mount bracket 6 Glue stubbed cut pipe into slip socket After glue is cured hand...

Страница 7: ...4 Slide roof into pump mounting bracket over motor WARNING When pressurizing the system gradually allow water to flow Shocking the meter by over speeding it with high flow rates can damage the interna...

Страница 8: ...stem 1 Remove the tank from carton 2 Verify the riser is still fully engaged in the Vortech plate 3 Place a piece of duct tape over the riser tube so no media enters the riser while filling 4 Make sur...

Страница 9: ...nimum of 1 2 Backwash flow rates in excess of 7 gpm or length in excess of 20 require 3 4 drain line Commercial drain lines should be the same size as the drain line flow control 4 The inlet on the by...

Страница 10: ...by pressing the Extra Cycle button for five seconds The Parameter Display displays the current Cycle Step BW RR etc during backwash and the data display counts down the time remaining for that cycle...

Страница 11: ...d backwash time when the number of days since the last backwash equals the backwash day override value Day of the Week Control This control regenerates the system on a weekly schedule The schedule is...

Страница 12: ...or do not appear in filter mode Entering Master Programming Mode Set the Time Of Day display to 12 01 P M Press the extra cycle Then press and hold the Up and Down buttons together until the programmi...

Страница 13: ...2 in Service C Unit Capacity Unit Capacity Grains H Feedwater Hardness Hardness of Inlet Water RS Reserve Selection Percentage Safety Factor rc Fixed Reserve Capacity SF Safety Factor Percentage of t...

Страница 14: ...preferably glass should be full of bubbles immediately after the sample is taken If not the installer will adjust the knob to 50 run the water for 10 15 minutes and check again 4 Continue adjusting th...

Страница 15: ...s an indication that the system is being overfed with H2O2 This occurs because after installation the water will become cleaner and the initial dosage of H2O2 may need to be adjusted to compensate for...

Страница 16: ...ter Open blow down valve and flush the filter 3 6 Months N A Injection Panel Pump Tube Inspect pump tube and replace as needed 2 Tube 1 5 Years 411 UCCP202 Injection Panel Duck Bill Check Valve Replac...

Страница 17: ...17 Flow Schematic Installation Operation and Maintenance Manual Oxi Gen Oxi 2P 3P 4P 5P 6P System...

Страница 18: ...ther casualty or if the original serial numbers have been removed Fouling or damage to the resin caused by iron sulfur bacterial iron silt sand tannins or ganics bacteria hot water or chlorine voids t...

Отзывы: