10
System Components
Carbon Filter Control Valve Features
Timer Features
Features of the SXT:
Power backup that continues to keep time and the passage of days for a minimum of 48 hours
in the event of power failure. During a power outage, the control goes into a power-saving
mode. It does not monitor water usage during a power failure, but it does store the days remain-
ing at the time of power failure.
Settings for both valve (basic system) and control type (method used to trigger a regeneration).
Day-of-the-Week controls.
While in service, the display alternates between time of day and days to regeneration.
The Service Icon flashes if a backwash cycle has been queued.
A backwash can be triggered immediately by pressing the Extra Cycle button for five seconds.
The Parameter Display displays the current Cycle Step (BW, RR, etc) during backwash, and the
data display counts down the time remaining for that cycle step. While the valve is transferring
to a new cycle step, the display will flash. The parameter display will identify the destination cy-
cle step (BW, RR, etc) and the data display will read "----". Once the valve reaches the cycle
step, the display will stop flashing and the data display will change to the time remaining. During
regeneration, the user can force the control to advance to the next cycle step immediately by
pressing the extra cycle button.
Installation, Operation and Maintenance Manual
Oxi-Gen Oxi-2P,3P,4P, 5P & 6P System
Error/
Information
Icon
S e r v i c e
I c o n
Extra Cycle
Button
U p
B u t t o n
D o w n
B u t t o n
x1000 Indicator
Flow Indicator
Parameter
Data
PM
Display
Display
Indicator
Programming
Icon