3. MAINTENANCE, TROUBLESHOOTING
3-5
Diagnostic test2
If the heading indication changes randomly when ship is at anchor or does not
change when the ship moves, run the test2 following the procedure below, with
the ship at anchor and satellite signal received.
Note:
Heading is not output during the diagnostic test, and this is communicated
with an appropriate message. After completing the diagnostic test, turn
the power off and on to update heading data.
1. Press the
MENU
key to open the menu.
2. Choose SYS SETUP and then press the
ENT
key.
3. Choose TEST? and then press the
ENT
key.
TEST1
TEST2
TEST3
Test menu options
4. Choose TEST2 and then press the
ENT
key.
TEST START?
(STOP: PWR OFF)
ARE YOU SURE?
YES
NO
Test start prompt
5. Press
◄
to choose YES and then press the
ENT
key.
6. Press the
ENT
key twice. Rate and angle values are 0.0
°
. If the values
increase or decrease markedly (with ship at anchor), suspect rate sensor
trouble. Contact your dealer to request service.
TEST2
RATE
ANGLE
YAW
ROL
PIT
0.0
°
0.0
°
0.0
°
0.0
°
0.0
°
0.0
°
<STOP: PWR OFF>
TEST2 display
7. Turn off the processor unit to quit the diagnostic test2.