![Furuno SC-50S Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/furuno/sc-50s/sc-50s_operators-manual_2349724039.webp)
2. OPERATION
2-11
11. Use the
Omnipad
to choose the baud rate of the equipment connected and
then press the
ENT
key.
12. INTERVAL is selected; press the
ENT
key.
25ms
100ms
200ms
1S
2S
Tx interval options
13. Use the
Omnipad
to choose appropriate output interval and then press the
ENT
key.
14. Choose IEC VERSION and then press the
ENT
key.
IEC ED1
IEC ED2
NMEA 1.5
IEC, NMEA version options
15. Choose appropriate IEC (or NMEA) edition and then press the
ENT
key.
16. Choose HDG TALKER and then press the
ENT
key.
GP
HE
HN
HC
Heading talker options
17. Choose appropriate heading talker and then press the
ENT
key.
GP: GPS navigator talker
HE: North-seeking gyrocompass talker
HN: Non-north seeking gyrocompass talker
HC: Magnetic compass talker
18. Press the
DISP
key to close the menu, or press the
MENU
key to return to
the I/O SETUP menu to setup another output port.