background image

FURUNO USA GMDSS

DESCRIPTION

RC1840

Mechanical Layout

FURUNO

Felcom 15

IC-215

Keyboard

AC Failure

Light

Meter

Handset

FM-8500

DSC-60

PP-510 for
Felcom 15

PP-510 for DSC-60

and DP-6

Label

AC Failure

Light

Meter

Handset

FM-8500

DSC-60

PP-510 for
Felcom 15

PP-510 for DSC-60

and DP-6

Label

IB-315

Junction Box

Printer Switch for

DSC-60 and DP-6

FURUNO

DP-6

Keyboard

FURUNO

USA

FURUNO

USA

Console Ground

Connection

Содержание RC18 Series

Страница 1: ...FURUNO USA A3 GMDSS CONSOLE MODEL RC18xx Series...

Страница 2: ...FURUNO USA IME GMD 40Z...

Страница 3: ...nections 3 1 RC18xx Battery Requirements 3 3 4 RC1815 RC1825 EQUIPMENT INSTALLATIONS 4 1 DMC 5 4 1 4 2 Felcom 15 4 2 4 3 FM 8500 4 3 4 4 FS 1570 FS 2570 4 4 4 5 IB 583 4 7 5 RC1815 RC1825 EQUIPMENT SE...

Страница 4: ...te 8 6 9 RC1840 EQUIPMENT LISTS FS 5000 9 1 DP 6 9 2 Felcom 15 9 3 FM 8500 9 5 DSC 60 9 6 GMDSS Installation Materials 9 7 Crate 9 7 10 RC18xx PARTS LIST 10 1 11 DRAWINGS RC1815 RC1825 Interconnect Dr...

Страница 5: ...h this equipment It has been placed in this format to ease installation and technical service As with the installation of any communications equipment careful planning is necessary Some of the most im...

Страница 6: ...for grounding purposes This grounding stud is located inside the back cover and should not be visible in a completed installation This is provided to assist in properly grounding the console and is t...

Страница 7: ...Handset FM 8500 FS 2570C PP 510 for Felcom 15 PP 510 for FS 2570C and IB 583 Label FURUNO IB 583 Keyboard FURUNO USA AC Failure Light Meter Handset FM 8500 FS 2570C PP 510 for Felcom 15 PP 510 for FS...

Страница 8: ...eter Handset FM 8500 DSC 60 PP 510 for Felcom 15 PP 510 for DSC 60 and DP 6 Label AC Failure Light Meter Handset FM 8500 DSC 60 PP 510 for Felcom 15 PP 510 for DSC 60 and DP 6 Label IB 315 Junction Bo...

Страница 9: ...A3 GMDSS Console Mechanical Drawing 2 4...

Страница 10: ...ry Negative TB1 1 in the Meter Box Assembly 2 Battery Positive TB1 2 in the Meter Box Assembly 3 1 3 Battery Charger The Battery Charger which is Dealer supplied attaches to TB1 in the Meter Box Assem...

Страница 11: ...Ships Mains 100 to 240 VAC 2 24 VDC Output Not Used PR 850A Rear Connections RC1815 and RC1825 1 Battery IN Negative TB1 5 Meter Box Assembly 2 Battery IN Positive TB1 6 Meter Box Assembly 3 AC Fail...

Страница 12: ...Felcom 15 TX 5A 2 2 5 2 5 2 5 IB 583 0 6A 0 6 0 6 FS 1570 RX 0 8A 0 8 FS 1570 TX 20A 2 10 FS 2570 RX 1 5A 1 5 FS 2570 TX 35A 2 17 5 FS 5000 RX 3A 3 FS 5000 TX 60A 2 30 FM 8500 RX 0 5A x 2 1 1 1 FM 85...

Страница 13: ...DMC 5 Junction Board Refer to Pg S 7 the RC1815 RC1825 DMC 5 Interconnect Drawing a VHF 1 FM 8500 b VHF 2 FM 8500 c FS 1570 FS 2570 d Felcom 15 IC 315 Junction Box The FS 1570 FS 2570 and FM 8500 s re...

Страница 14: ...n the console 3 Install the IC 305 Distress Alert Received Call Unit on the bridge Wire this to the IC 315 Junction box using Belden 85164 or equivalent Refer to Pg S 6 the Felcom 15 IC 315 Junction B...

Страница 15: ...ly All power connections outside the console must be protected with inline fuses The FM 8500 which draws 7 amps will require a 10 gauge wire for up to 40 feet separation from the Meter Box Assembly 5...

Страница 16: ...35 amps will require a 6 gauge wire for up to 40 feet separation from the PR850A power supply 3 Connect the cable Controller 1 connected to the FS 2570C to the transceiver port Controller 1 4 4 3 Ant...

Страница 17: ...gh 2 4 of the Installation Manual 7 Reinstall the antenna coupler housing using only a couple of the provided screws This will allow easier access when testing the unit later in the installation 4 4 5...

Страница 18: ...Continued 4 Reassemble the transceiver 4 4 6 NMEA IEC 61162 Connection 1 Install a cable Belden 8302 or equivalent from the Felcom 15 Junction Box to the FS 1570 FS 2570 transceiver Connect this cable...

Страница 19: ...Using the four tapping screws provided Refer to Pg 2 2 the RC1815 and RC1825 Mechanical Layout and Pg 4 4 of the Installation Manual 4 5 2 Power Connections 1 Connect power cable IB 583 Power to the...

Страница 20: ...VHF2 e DMC 5 optional 4 Each piece of equipment goes through a self test on start up and will show any errors discovered during this process Record any errors for future reference 5 1 2 E Meter 1 The...

Страница 21: ...hen the 0 key four times 3 Then press the ENT key 5 2 2 VHF Input 1 Press the SET UP key then the 4 VHF key 2 Press the SELECT to highlight No 1 then press the ENT key 5 2 3 MF HF Input 1 The display...

Страница 22: ...2 5 Time and Date 1 The display should appear as shown above if it does continue to step 2 If not record the error and check the appropriate equipment 2 Press the SELECT key then the ENT key 3 Enter t...

Страница 23: ...ow key highlight IMN and then press the Enter key 2 Type in the IMN and press the Enter key 3 Press the Esc key The screen will now prompt Update Select Yes and press the Enter key 4 Press the Esc key...

Страница 24: ...connections Refer to Pg S 6 the Felcom 15 IC 315 Junction Box Connections 5 4 2 MMSI Setting 1 Press the SELECT key the Setup menu appears 2 Press the 9 key the System menu appears 3 Using the arrow k...

Страница 25: ...1 Using the arrow keys select RT and press the ENT key 2 Press the 2 key to select USA WX ON then press the ENT key 5 4 5 Protection Setting 1 Using the arrow keys select P and press the ENT key 2 Pre...

Страница 26: ...If the tune fails verify the antenna grounding system and the coupler connections 5 5 3 MMSI 1 To set the MMSI refer to the Dealers Manual Pg 4 5 5 4 Manual 2182 kHz Tuning Preset 1 Press the 1 RT 218...

Страница 27: ...ess the F5 key to enter the Station menu 2 Press the key to select the ID to be entered 6 Group ID Entry 4 5 digit 7 Group ID Entry 9 digit 8 Select ID Entry 4 5 digit 9 Select ID Entry 9 digit If an...

Страница 28: ...Junction Board Refer to Pg S 8 the RC1840 DMC 5 Interconnect Drawing a VHF 1 FM 8500 b VHF 2 FM 8500 c DSC 60 d Felcom 15 IC 315 Junction Box The DSC 60 and FM 8500 s require a cable with two twisted...

Страница 29: ...81 6 box 2 Attach the provided ground wire between the rear of the Main Unit and the ship s ground system 6 2 2 Terminal Unit 1 Install the DP 6 Terminal hanger bracket on the left side of the console...

Страница 30: ...e DSC 60 and change the jumper on the RCVR board from active to passive Refer to Pg 20 Preamp Settings of the Installation Manual 3 When reinstalling the DSC 60 in the console be sure to attach the ca...

Страница 31: ...le 3 Install the IC 305 Distress Alert Received Call Unit on the bridge Wire this to the IC 315 Junction box using Belden 85164 or equivalent Refer to Pg S 6 the Felcom 15 IC 315 Junction Box Connecti...

Страница 32: ...y All power connections outside the console must be protected with inline fuses The FM 8500 which draws 7 amps will require a 10 gauge wire for up to 40 feet separation from the Meter Box Assembly 5 M...

Страница 33: ...ding the cable clamp Install a 50mm width copper strap between the cable holder and the ship s hull or ground system Refer to Pg 3 13 of the Installation Manual 5 Leave the transceiver covers open The...

Страница 34: ...connection provided at the base of the antenna coupler Make certain this connection is brazed or welded to the ship s hull or ground system The exposed ground strap should be painted or coated with a...

Страница 35: ...and VHF2 f DMC 5 optional 4 Each piece of equipment goes through a self test on start up and will show any errors discovered during this process Record any errors for future reference 7 1 2 E Meter 1...

Страница 36: ...the 0 key four times 3 Then press the ENT key 7 2 2 VHF Input 1 Press the SET UP key then the 4 VHF key 2 Press the SELECT to highlight No 1 then press the ENT key 7 2 3 MF HF Input 1 The display sho...

Страница 37: ...Time and Date 1 The display should appear as shown above if it does continue to step 2 If not record the error and check the appropriate equipment 2 Press the SELECT key then the ENT key 3 Enter the Y...

Страница 38: ...he F5 key to enter the Station menu 2 Press the key to select the ID to be entered 6 Group ID Entry 4 5 digit 7 Group ID Entry 9 digit 8 Select ID Entry 4 5 digit 9 Select ID Entry 9 digit If an incor...

Страница 39: ...ual DSC 60 7 4 1 General 1 Power up the unit 2 Press the 3 TEST key to start the self test 3 The test will run automatically and print the results 4 Verify all test are OK and press the CANCEL key to...

Страница 40: ...ey highlight IMN and then press the Enter key 2 Type in the IMN and press the Enter key 3 Press the Esc key The screen will now prompt Update Select Yes and press the Enter key 4 Press the Esc key unt...

Страница 41: ...ections Refer to Pg S 6 the Felcom 15 IC 315 Junction Box Connections 7 6 2 MMSI Setting 1 Press the SELECT key the Setup menu appears 2 Press the 9 key the System menu appears 3 Using the arrow keys...

Страница 42: ...ing the arrow keys select RT and press the ENT key 2 Press the 2 key to select USA WX ON then press the ENT key 7 6 5 Protection Setting 1 Using the arrow keys select P and press the ENT key 2 Press t...

Страница 43: ...llowing settings to meet GMDSS requirements a Power reduction on both 2182 and 2187 5 is disabled STO 9927 ENT 1 ENT b Minimum output power is 60W or more STO 9928 ENT 1 ENT c Enable BK RELAY This is...

Страница 44: ...TUNE key TX TUNING OK will appear when the tuning is complete 3 Open the coupler and record the status of the LED s CR1 CR23 Refer to Pgs 3 23 and 3 24 of the Operator s Installation Manual FS 5000 4...

Страница 45: ...Boxed Unit Item No Name Part No Qty 1 Marine VHF Radiotelephone FM 8500 1 2 Operator s Manual 1 3 Operator s Guide 1 4 Installation Manual 1 5 Procedure for Distress Transmission on VHF FM 8500 1 6 C...

Страница 46: ...r Distress Transmission on VHF and HF 2 5 Antenna Coupler AT 1560 15 or AT 1560 25 1 6 Transciever FS 1570 or FS 2570 1 7 Copper Strap 000 572 187 1 8 Rubber Sleeve 000 130 472 1 9 Tapping Screw 000 8...

Страница 47: ...13 1 9 15 Amp Fuse 000 549 014 1 10 Tapping Screw 000 802 081 4 11 Copper Strap 1 2M 590 300 310 1 12 Label C S D 100 248 060 1 13 Label 100 248 051 1 14 Velcro 60mm 100 237 680 4 15 Velcro 30mm 100 2...

Страница 48: ...538 113 4 4 Crimp on Lug 000 108 424 1 Item No Name Part No Qty 1 IC 306 Alarm Unit 1 2 Tapping Screw 000 802 079 4 3 Crimp on Lug 000 538 113 4 4 Crimp on Lug 000 108 424 1 Item No Name Part No Qty...

Страница 49: ...00 248 051 1 9 Velcro 60mm 100 237 680 4 10 Velcro 30mm 100 237 670 4 GMDSS Installation Materials Item No Name Part No Qty 1 28 v Bulb RC1 800 020 1 2 2 Amp Fuse Mini ATM RC1 800 026 3 3 PL259 Connec...

Страница 50: ...8 RC1815 RC1825 Equipment Lists Crate Item No Name Part No Qty 1 RC1800 Rack FUSA1800 1 2 FS 2570C Control Head 1 3 FM 8500 VHF w DSC 1 4 PP 510 Printer 2 8 6...

Страница 51: ...0 056 874 1 3 Handset 000 112 623 1 4 Handset Hanger 005 011 950 1 5 Frequency Table 005 925 890 1 6 Crimp on Lug FV1 25 3 000 538 113 4 7 Crimp on Lug FV1 25 4 000 538 114 1 8 Hex Bolt 000 800 054 4...

Страница 52: ...B25 000 120 946 2 DP 6 Terminal Unit Item No Name Part No Qty 1 Grounding Wire 000 108 138 1 2 Cable 000 127 108 1 3 Tapping Screw 6 x 20 000 802 084 4 4 Label Inmar 100 217 010 1 5 Velcro Fastener 30...

Страница 53: ...9 15 Amp Fuse 000 549 014 1 10 Tapping Screw 000 802 081 4 11 Copper Strap 1 2M 590 300 310 1 12 Label C S D 100 248 060 1 13 Label 100 248 051 1 14 Velcro 60mm 100 237 680 4 15 Velcro 30mm 100 237 6...

Страница 54: ...113 4 4 Crimp on Lug 000 108 424 1 Item No Name Part No Qty 1 IC 306 Alarm Unit 1 2 Tapping Screw 000 802 079 4 3 Crimp on Lug 000 538 113 4 4 Crimp on Lug 000 108 424 1 Item No Name Part No Qty 1 Ca...

Страница 55: ...xed Unit Item No Name Part No Qty 1 Marine VHF Radiotelephone FM 8500 1 2 Operator s Manual 1 3 Operator s Guide 1 4 Installation Manual 1 5 Procedure for Distress Transmission on VHF FM 8500 1 6 Conn...

Страница 56: ...Pin 000 116 185 1 2 Connector FM 14 7 Pin 000 113 345 1 3 Connector FM MP 7 000 108 859 1 4 Reducer MP 7 MP M3A 000 108 860 1 5 Reducer MP 7 MP M5A 000 108 861 1 6 Installation Manual 1 7 Operator s M...

Страница 57: ...inter Operator s Manual 2 6 Shore Based Maintenance Certificate 1 7 Warranty Registration Form 1 8 E Meter Owners Manual 1 9 Installation Manual IME GMD 40Z 1 10 Dealers Manual OSE GMD 20Z 1 11 Daily...

Страница 58: ...00 011 4 Meter RC1 500 067 5 AC Failure Light Assy RC1 500 069 6 AC Failure Light Label RC1 500 068 7 Furuno USA GMDSS Label RC1 800 034 8 Bulb 3w 24v equiv to 1820 RC1 800 020 9 Fuses 2 Amp Mini ATM...

Страница 59: ...or AT 1560 25 D ANT Main Unit Controller 1 Coupler T R ANT Handset 1 PP 510 Keyboard Printer Switch NBDP DTE Printer Printer A B COM FS 1570 or FS 2570 000 130 484 000 113 360 000 056 950 000 146 652...

Страница 60: ...C 305 AT 5000 D ANT Coupler TX ANT Handset Keyboard NBDP 24 VDC from PR850A Notes 1 Local Supplied Factory Supplied 2 All External Connections Must be Fused 3 Two FM 8500 s supplied with each console...

Страница 61: ...5 6 20 7 10 11 12 13 14 12 13 14 15 16 17 18 19 20 REMOTE A Line Out H Line Out C Line In H Frame Grnd TXD H RXD H Ground Line In C TX Key REMOTE B RT Frame Grnd TXD H RXD H Ground Line Out H Line Ou...

Страница 62: ...Battery Negative Battery Positive Charger Negative Charger Positive Battery In Negative Battery In Positive 24VDC AC Fail Negative AC Fail Positive PR850A Battery IN AC Fail Circuit 24 VDC Output Inl...

Страница 63: ...SHUNT Meter Wiring 1 Black 2 Blue 3 Brown 4 Red 5 Jumper to 4 Ground 1 2 Emergency Light Cable Notes 1 Local Supplied Factory Supplied 2 All External Connections Must be Fused AC Fail Light AC Fail Li...

Страница 64: ...2 13 14 15 1 3 2 4 5 6 7 8 9 10 11 12 13 14 15 VCC GND TD RD A TD RD B N C TD A TD B RD A RD B GND DMC OUT H DMC OUT C DMC IN H DMC IN C DMC CTR DMC NAV IC 305 306 Output Sentences GGA ZDA GLL VTG RMC...

Страница 65: ...GND TD4 A TD4 B RD4 A RD4 B GND DIST_CTR TB5 INMARSAT SES 11 13 12 14 15 Felcom 15 IC 315 Junction Box DMC_OUT H DMC_OUT C DMC_IN H DMC_IN C Frame Grnd DMC_CTR 1 3 2 4 5 P P DIST_IN H GND 6 DIST_IN C...

Страница 66: ...T C DMC IN H DMC IN C FRAME GRND DMC CTR TB5 INMARSAT SES 11 13 12 14 15 Felcom 15 IC 315 Junction Box DMC_OUT H DMC_OUT C DMC_IN H DMC_IN C Frame Grnd DMC_CTR 1 3 2 4 5 P P DIST_IN H GND 6 DIST_IN C...