1. OPERATION
15
1.14
How to Choose a Transceiver
If your FE-800 is connected to two transceivers, you can switch between the transceivers using
the procedure below.
Note:
If [FE-8020 No.2] is not enabled in the [Service Menu], this menu is not selectable.
To enable [FE-8020 No.2], consult a FURUNO technician.
1. Press the
MENU/ESC
key to open the Main menu.
2. Select [FE-8020 Select] using
or
, then press the
ENT
key. This will open a pop-up
window.
3. Select the appropriate transceiver using
or
, then press the
ENT
key to apply the settings
and close the pop-up window. The available options are [No.1] or [No.2]. The message
"Changing settings..." is displayed while the FE-800 obtains data from the transceiver. When
the message disappears, the switch between transceivers is complete.
4. Press the
MENU/ESC
key once to close the menu.
1.15
How to Set the Depth Below Surface (DBS)
The depth reading can be referenced from one of three points.
To choose which setting to use, do the following:
1. Press the
MENU/ESC
key to open the Main menu.
2. Select [Sounder] using
or
, then press the
ENT
key.
Reference point
Description
Transducer
Depth from transducer to seabed (requires transducer “below waterline”
measurement.)
Surface
Depth from surface to seabed (requires Draught input, see section 1.16.)
Keel
Depth from keel to seabed (requires keel depth setting. Consult your local
FURUNO dealer.)
Draught
*1
Offset
*2
Keel
Seabed
*1: Set the draught on [Draught] menu.
*2: Set the offset for transducer on [KEEL] menu (service menu).
Sea surface based
water depth
Transducer based water
depth
Keel based water depth
Surface
Transducer