APPX. 4 ALERT MESSAGES
AP-9
Alert I/F1, Legacy
*: Depending on setting for [Bottom Lost Priority] selected at installation, BOTTOM LOST may be
output as a Category B Caution, with the ID 003.
Alert Title
Alert Text
Priority/
Category
Alert
ID
Meaning
Measures
SHAL-
LOW
DEPTH
Depth below
keel alarm.
Alarm/A
230
Depth below the Keel is too
shallow.
Check the depth
visually.
LOST
MEAS
TCVR1 TX
voltage ERR
stopped
MEAS.
Warning/B
101
Transceiver 1 PWR board or
TRX board may be damaged.
Voltage is not within safe
guidelines.
Consult a FU-
RUNO techni-
cian.
TCVR1 RX
voltage ERR
stopped
MEAS.
Warning/B
102
Transceiver 1 PWR board or
TRX board may be damaged.
Voltage is not within safe
guidelines.
TCVR1 tem-
perature
ERR stopped
MEAS.
Warning/B
103
Transceiver 1 Temperature is
above safe guidelines.
TCVR2 TX
voltage ERR
stopped
MEAS.
Warning/B
111
Transceiver 2 PWR board or
TRX board may be damaged.
Voltage is not within safe
guidelines.
TCVR2 RX
voltage ERR
stopped
MEAS.
Warning/B
112
Transceiver 2 PWR board or
TRX board may be damaged.
Voltage is not within safe
guidelines.
TCVR2 tem-
perature
ERR stopped
MEAS.
Warning/B
113
Transceiver 2 Temperature is
above safe guidelines.
BOTTOM
LOST *
Bottom losts.
Warning/B
(Caution/B)
001
(003)
Seabed at fore transducer
cannot be detected
Check that the
seabed is within
range. If the
problem recurs,
consult a FURU-
NO technician.
LOST
DISP
DISP COM
ERR stops
display up-
date.
Caution/B
301
Communication error be-
tween display unit and trans-
ceiver 1.
Consult a FU-
RUNO techni-
cian.
LOST
TCVR
TCVR2 COM
ERR stops
MEAS.
Caution/B
302
Communication error be-
tween display unit and trans-
ceiver 2.
FAN
SPEED
LOW
CVR1 fan
ERR may
stop MEAS.
Caution/B
104
Fan No.1 speed lower than
minimum speed on transceiv-
er 1.
TCVR2 fan
ERR may
stop MEAS.
Caution/B
114
Fan No.2 speed lower than
minimum speed on transceiv-
er 2.
BOTTOM
LOST
Bottom outs
of range.
Caution/B
002
Seabed is out of range and
cannot be detected.