AP-7
APPX. 4 ALERT MESSAGES
The alert modes Alert I/F1, Alert I/F2 and Legacy settings are set during the initial installation.
Consult a FURUNO technician to change these settings.
Alert I/F2
Alert Title
Alert
Description
Text
Priority/
Category
Alert ID,
Instance
Meaning
Measures
SHALLOW
DEPTH
TCVR1 FORE
depth below
keel alarm.
Alarm/A
3031, 1
Depth at fore transducer is
shallower than that set for
the alarm.
Check the
depth visually.
TCVR1 AFT
depth below
keel alarm.
Alarm/A
3031, 2
Depth at aft transducer is
shallower than that set for
the alarm.
TCVR2 FORE
depth below
keel alarm.
Alarm/A
3031, 3
Depth at fore2 transducer
is shallower than that set
for the alarm.
TCVR2 AFT
depth below
keel alarm.
Alarm/A
3031, 4
Depth at aft2 transducer is
shallower than that set for
the alarm.
LOST
MEAS
TCVR1 TX volt-
age ERR
stopped
MEAS.
Warning/B
3008, 1
Transceiver 1 PWR board
or TRX board may be dam-
aged. Voltage is not within
safe guidelines
Consult a FU-
RUNO techni-
cian.
TCVR2 TX volt-
age ERR
stopped
MEAS.
Warning/B
3008, 4
Transceiver 2 PWR board
or TRX board may be dam-
aged. Voltage is not within
safe guidelines.
TCVR1 RX
voltage ERR
stopped
MEAS.
Warning/B
3008, 2
Transceiver 1 PWR board
or TRX board may be dam-
aged. Voltage is not within
safe guidelines.
TCVR2 RX
voltage ERR
stopped
MEAS.
Warning/B
3008, 5
Transceiver 2 PWR board
or TRX board may be dam-
aged. Voltage is not within
safe guidelines.
TCVR1 tem-
perature ERR
stopped
MEAS.
Warning/B
3008, 3
Transceiver 1 Tempera-
ture is above safe guide-
lines.
TCVR2 tem-
perature ERR
stopped MEAS
Warning/B
3008, 6
Transceiver 2 Tempera-
ture is above safe guide-
lines.