background image

GENERAL CHARACTERISTICS

1. Rules and Regulations

CCIR Rec. 493 (Class A), 541
IMO Res. A609 (15), CEPT TR/34-01

2. Distress Call and Message

Distress Call and Message (RR3112: Format specifier
(distress), Self-ID, Nature of distress, Distress coordinates,
Time, Telecommand, EOS, ECC)

3. Class of Emission

DSC: F1B/J2B (J2B w/FS-1562)
Voice:J3E, H3E (2182 kHz)
TTY:

F1B/J2B (J2B w/FS-1562)

4. Manual Setting or Scan of Distress Frequencies

MF/HF DSC:
2187.5, 4207.5, 6312, 8414.5, 12577, 16804.5 kHz
Corresponding MF/HF NBDP (not scanned):
2174.5, 4177.5, 6268, 8376.5, 12520, 16695 kHz
TP: 2182, 4125, 6215, 8291, 12290, 16420 kHz

5. Message Storage

Receive:
50 distress messages max. plus 50 non-distress messages
Transmit:
50 non-distress messages plus 99 files containing station ID,
telephone no., frequency, etc.

6. Nav Data

IEC61162

7. Alarms

Aural and visual on receipt of distress, urgency or general
calls

8. Display

24 characters x 2 lines
Character composition: 5 x 7 dots
LCD with adjustable backlighting

9. Modulator and Demodulator
Level:

-30 dBm to +10 dBm at 600 ohms, balanced

Frequency: Mark 1615 Hz, Space 1785 Hz, 100 baud
Stability: ±0.5 Hz  

RECEIVER CHARACTERISTICS OF DSC-6A

Receive Frequency: 2187.5 kHz
Sensitivity: Error rate 1 % at 0 dBµV

POWER SUPPLY

10.8 - 40.0 VDC, 15 W
115/230 VAC thru AC/DC changeover supply

EQUIPMENT LIST

Standard
1. DSC terminal
2. Installation materials and spare parts
Optional
1. Mounting bracket
2. Printer PP-500

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

SPECIFICATIONS OF DSC-6/6A

99043N Printed in Japan

24 VDC

VCTF-1.25 

x 2C, 3 m

Operator’s room

Distress 
message 
controller 
DMC-5

Centralized control/monitoring

Captain’s room

CO-SPEVV

-SB-C 

0.2 x 2 P

, 30 m max.

Alarms

DSC-6/6A standard system 

PRINTER
PP-500/510 

115 or 230 VAC

24 VDC

Position data

Distress alarms

ALLWAVE RECEIVER 
RV-107

DPYC-1.25

57FE-338-205W, 5 m

Setting telecommand, 
working freq., etc.

CO-SPEVV

-SB-C, 

0.2 x 2P

, 30 m max

(2 ports for MF/HF 

DSC and VHF DSC)

NAV

NBDP Terminal 

DP-5/6

MF/HF DSC
RECEIVER 
AA-50

Option

Setting telecommand, 
working freq., etc.

DSC distress 
and safety
(continuous watch)

DSC signal,
telephony,
telex

DSC ship business and routine 
(scanning watch)

DSC signal,
telephony,
telex

DSC distress 
and safety
(continuous watch)

DSC ship business and routine 
(scanning watch)

NA

VTEX Receiver NX-500

2182 W

atch receiver 

AA-45B

EGC Receiver EGC-5

DSC-6/6A

FS-1562

For DSC-6A

DPYC-1.25

(For PP-500)

(For PP-510)

FS-1562

NBDP Terminal 

DP-5/6

MF/HF DSC
RECEIVER 
AA-50

DSC-6/6A

For DSC-6A

299  11.8"

258  10.2"

143  5.6"

(95  3.7")

(95  3.7")

6 -

˘

7.5

254.1  10.0"

127  5.0"

89  3.5"

(89  3.5")

Weight: 3.5 kg  

FURUNO U.S.A., INC.

Camas, Washington, U.S.A.
Phone: +1 360-834-9300 Telefax: +1 360-834-9400

FURUNO (UK) LIMITED

Denmead, Hampshire, U.K.
Phone: +44 1705-230303   Telefax: +44 1705-230101

FURUNO FRANCE S.A.

Bordeaux-Mérignac, France
Phone: +33 5 56 13 48 00  Telefax: +33 5 56 13 48 01

FURUNO ESPANA S.A.

Madrid, Spain
Phone: +34 91-725-90-88   Telefax: +34 91-725-98-97

FURUNO DANMARK AS

Hvidovre, Denmark
Phone: +45 36 77 45 00   Telefax: +45 36 77 45 01

FURUNO NORGE A/S

Ålesund, Norway
Phone: +47 70 102950   Telefax: +47 70 127021

FURUNO SVERIGE AB

Västra Frölunda, Sweden
Phone: +46 31-7098940   Telefax: +46 31-497093

FURUNO SUOMI OY

Helsinki, Finland
Phone: +358 9 3417570   Telefax: +358 9 3415716

Отзывы: