126 VAC, consider installing a Furman voltage regulator.
SERVICE
If you require technical support or equipment service, please contact the Furman Service Department at 707-763-1010. You may
also email [email protected].
All equipment being returned for repair must have a Return Authorization (RA) number. To get an RA number, please call the
Furman Customer Service Department.
Before returning any equipment for repair, please be sure that it is adequately packed and cushioned against damage in shipment,
and that it is insured. We suggest that you save the original packaging and use it to ship the product for servicing. Also, please pro-
vide a note giving your name, address, phone number, RA number and a description of the problem.
5 YEAR LIMITED WARRANTY
SAVE YOUR SALES RECEIPT! The receipt is your proof of purchase and confirms the product was purchased at an authorized Furman
dealer. It will need to be submitted to Furman in order to process any warranty claims.
Furman, a brand of Panamax Inc., warrants its PL-PRO DMC (the “Product”) as follows:
Furman warrants to the original purchaser of the product that the product sold hereunder will be free from defects in material and
workmanship for a period of five years from the date of purchase. If the product does not conform to this Limited Warranty during
the warranty period (as herein above specified), purchaser shall notify Furman of the claimed defects by calling 707-763-1010 or
via email ([email protected]). If the defects are of such type and nature as to be covered by this warranty, Furman
shall authorize purchaser to return the product to Furman headquarters. Warranty claims MUST be accompanied by a copy of the
original purchase invoice or receipt showing the purchase date. Shipping charges to Furman headquarters must be prepaid by the
purchaser of the product. Furman shall, at its own expense, furnish a replacement product or, at Furman’s option, repair the defec-
tive product. Return shipping charges back to purchaser will be paid by Furman.
THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED
munication devices by simply plugging the re-charge cord into the front panel socket. Please note that as there are currently many
standards for USB, some devices may not be compatible with our charger.
TRANSFORMER PLUG (WALL WART) SECURING LOOPS:
Your 20 amp Furman Classic Pro Series conditioner features rear panel AC outlets that are widely spaced for plug transformers (wall
warts). Additionally, these may be secured for transport with hook and loop straps (included). Each outlet has threaded screw
holes on either side to accommodate the hook and loop straps.
TROUBLESHOOTING
1.) Symptom: No power to the AC outlets.
Possible Cause: The circuit breaker (located on the front panel) has tripped due to excessive load.
Action Needed: Unplug one piece of equipment from the Furman conditioner and manually turn the unit off, then on again.
2.) Symptom: No power to the AC outlets, “Protection OK” indicator is not lit.
Possible Cause: Either the AC outlet to which your Furman conditioner is connected has no AC voltage present, or the protection
circuitry in your unit has been compromised.
Action Needed: Plug the Furman conditioner into an AC receptacle where a nominal 120 VAC is present. If the problem persists,
contact Furman for service.
3.) Symptom: Extreme Voltage (EVS) indicator lit.
Possible Cause: Input voltage is above 140V causing power to the unit’s outlets to be shut down. Additionally, if the voltage is
below 85V – 90V at turn on, the unit will not allow AC voltage to reach the outlets.
Action Needed: Correct the line voltage, then turn the Furman conditioner on. If the voltage present is below 114 VAC or above