Furman PL-PRO DMC Скачать руководство пользователя страница 6

6

PL-PRO DMC OWNER’S MANUAL

lamps are not in use, we recommend turning the dimmer fully counterclockwise, or pushing the knob to the off setting to maximize 
the life of the LED’s.  Whether the light tubes are fully extended or flush with the front panel, there will be no appreciable heat regard-
less of the dimmer setting due to the efficiency of our full light spectrum LED’s.  

All Furman Classic Series Conditioners feature a rear rack BNC socket which will accept any 12 VAC (0.5A) gooseneck lamp assembly 
(such as the Furman GN-LED or GN-I).  Simply slide the BNC plug over the socket and rotate clockwise until the connector snaps into 
the locked position.  The rear rack lamp can be powered on or off with the rear light switch which is adjacent to the BNC connector.  

ULTRA-LOW RESISTANCE MAGNETIC POWER SWITCH / CIRCUIT BREAKER:

Furman’s Classic Series 20 amp capacity power switch is specifically designed to stand up to the enormous high in-rush current de-
mands of many power amplifiers.  Additionally, Furman magnetic circuit breakers are not sensitive to temperature, and will not raise 
the AC impedance as do many, less costly thermal breaker.  If the 20 amp RMS current capacity of the PL-PRO C is exceeded, the spring 
tensioned-switch will immediately switch to the off position.  You will need to switch the toggle back to the on position once the prob-
lem is corrected (typically by eliminating one component, or until the RMS current does not exceed 20 amps or 2400 watts).

EXTREME VOLTAGE SHUTDOWN (EVS) INDICATOR:

The Extreme Voltage LED indicator is normally off.  It is located within the meter lens assembly directly above the blue voltage / cur-
rent LED’s, though during normal use it will NOT be visible.    

The Extreme Voltage indicator monitors a hazard common in the entertainment, remote broadcast, and AV contractor industries: wir-
ing faults.  For example: accidental connection to 208VAC where 120VAC is expected, or an open series neutral from a 208 to 240VAC 
electrical service. The Furman EVS circuit senses voltages that are so high that operation would be impossible and shuts the power 
down before damage can occur.  

Upon initially applying power to these units, the Extreme Voltage indicator will light and a red “Extreme Voltage” label will appear at 
the top of the meter lens if the input voltage is above the extreme voltage cutoff. 

NOTE:

 If the mains power is above the high cutoff voltage and has caused the EVS circuit to remove power from the PL-PRO DMC’s 

outlets, it cannot restore power without the operator manually turning the unit off, then on again.  Avoid turning the unit back on 
without first checking the source of the problem and changing the AC source (if necessary).

PROTECTION OK INDICATOR:

Although the Furman SMP circuit assures virtually maintenance-free protection from transient voltage spikes and surges, nature has a 
way of occasionally creating electrical forces that are beyond the capabilities of ANY surge suppression device to absorb without some 
degree of damage (such as a direct lightning hit in an outdoor application).  In the rare instance that this occurs, the green “Protection 
OK” LED indicator, located at the bottom right of the meter lens assembly, will dim. If this happens, some level of protection from volt-
age surges will remain, but the PL-PRO DMC’s clamping voltage rating will be compromised and the unit must be returned to Furman 
for service. 

NOTE:

 Furman’s Classic Series power conditioners do not compensate for high or low AC line voltage. If you frequently move your 

rack to different locations, derive power from generators, use very long extension cords, travel internationally, or are in an area prone 
to brownouts, you may benefit from the use of one of Furman’s AC Voltage Regulators.

SWITCHABLE DIGITAL VOLTAGE AND TRUE RMS CURRENT METER:   

Furman’s laboratory precision AC digital voltmeter continually measures incoming voltages within a typical tolerance of +/-1.5VAC.  It 
should be noted that the voltage reading is incoming.  

Furman’s laboratory precision True RMS digital current meter continually measures the total circuit AC load, within a typical tolerance 
of +/- 0.5 amp.  Because these meters feature true RMS technology, the current readings are accurate regardless of load conditions 
(capacitive, inductive, or resistive). To switch between voltage and current, press the button labeled “Line Voltage/Current”. Hold this 
button down for two seconds to dim the brightness of the display.

VOLTAGE RANGE INDICATOR:

This indicator is located in the lower left corner of the digital volt / amp meter lens assembly.  When AC voltage is within 5 volts (+/-) of 
a nominal 120VAC source, this tri-color indicator will be green (optimal).  However, if the voltage is between 110 to 114VAC or be-
tween 126 to 130VAC, the indicator will turn amber (caution - not optimal).  If the incoming voltage is in an extreme range (below 110 
or above 130), the indicator will turn red.  This range is far from optimal, and may be potentially damaging to some equipment.

USB CHARGER:

The Furman PL-PRO C’s USB charger provides an easy way to recharge many popular electronic accessories as well as cellular com-

Содержание PL-PRO DMC

Страница 1: ......

Страница 2: ......

Страница 3: ...ALL CONTENT 2008 FURMAN ALL RIGHTS RESERVED PRINTED IN CHINA ENGLISH Page 4 FRANÇAIS Page 10 ESPAÑOL Page 16 PL PRO DMC OWNER S MANUAL PL PRO DMC GUIDE DE L UTILISATEUR PL PRO DMC MANUAL DEL PROPIETARIO ...

Страница 4: ...ment when the protection device is subjected to a transient surge or spike While other designs offer clamping voltages that are well above 330 Vpk Furman s SMP clamps at 188 Vpk 133 VAC RMS even when tested with multiple 6000 Vpk 3000 amp surges This unprecedented level of protection is only available with Furman s SMP technology EVS EXTREME VOLTAGE SHUTDOWN Furman s trusted over voltage EVS circu...

Страница 5: ... or other appliances that produce extreme heat 4 The Furman PL PRO DMC should only be connected to a 120 VAC 50Hz 60Hz 20 amp grounded electrical outlet Do not defeat the ground or change polarization of the power plug 5 Route the AC power cord and other cables so that they are not likely to be walked on tripped over or stressed Pay particular attention to the condition of the cords and cables at ...

Страница 6: ...he PL PRO DMC s outlets it cannot restore power without the operator manually turning the unit off then on again Avoid turning the unit back on without first checking the source of the problem and changing the AC source if necessary PROTECTION OK INDICATOR Although the Furman SMP circuit assures virtually maintenance free protection from transient voltage spikes and surges nature has a way of occa...

Страница 7: ...e Shipping charges to Furman headquarters must be prepaid by the purchaser of the product Furman shall at its own expense furnish a replacement product or at Furman s option repair the defec tive product Return shipping charges back to purchaser will be paid by Furman THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED munication devices by ...

Страница 8: ...any part thereof whether based on contract tort strict liability or otherwise Under no circumstances whether based on this Limited Warranty or otherwise shall Furman be liable for incidental special or consequential damages This Limited Warranty states the entire obliga tion of Furman with respect to the product If any part of this Limited Warranty is determined to be void or illegal the remainder...

Страница 9: ... outlet dual pull out lamps wall wart spacing for large transformers bnc lamp connector bnc lamp power switch isolated ac outlet banks 10 ft 12 gauge power cable front lamp dimmer meter control button master power switch digital led voltmeter ammeter and status indicators usb charger ...

Страница 10: ...surtensions doivent être réparés lorsqu exposés à des pointes de tension transitoires impliquant le démantèlement de votre système Ce n est pas le cas avec le circuit SMP de Furman Les voltages transitoires nuisibles sont absorbés contraints et dissipés de façon sécuritaire Votre équipement branché est protégé tandis que votre appareil Furman se protège lui même Ce qui différencie le circuit SMP d...

Страница 11: ...a pluie ou à l humidité Le boîtier comporte des niveaux de tensions élevés Ne retirez pas le couvercle Confiez toujours l entretien à des techniciens qualifiés Le symbole représentant un éclair avec une tête de flèche indique qu il y a présence de tension non isolée dans le boîtier qui dans le cas où sa magnitude est suffisante constitue un risque de choc électrique IMPORTANTES CONSIGNES DE SÉCURI...

Страница 12: ... beaucoup de disjoncteurs thermiques moins dispendieux Si la capacité de 20 ampères RMS du PL PRO C est dépassée l interrupteur à ressort se mettra automatiquement en position éteinte Vous devrez remettre l interrupteur en position de marche une fois que le problème sera réglé typiquement vous devrez éliminer une composante ou attendre que le courant RMS n excède pas 20 A ou 2400 watts INDICATEUR ...

Страница 13: ...tte gamme est loin d être optimale et pourrait potentiellement endommager certains équipements CHARGEUR USB Le chargeur USB du PL PRO C de Furman constitue une façon pratique de recharger beaucoup d accessoires électroniques popu laires et des appareils de communication cellulaire simplement en branchant le cordon de chargement dans la prise située sur le panneau avant Veuillez prendre note qu il ...

Страница 14: ...r à retourner le produit à son siège social Les réclamations sous garantie doivent être accompagnées d une copie de la facture ou du reçu d achat original indiquant la date d achat Les frais d envoi doivent être payés à l avance par l acheteur du produit Furman s engage à remplacer le produit à ses frais ou selon son jugement à réparer le produit défectueux Les frais d envoi à l acheteur seront pa...

Страница 15: ...m anodisé noir brossé de 0 120 po circuits imprimés sur verre époxyde CONSOMMATION 15 VA LISTE D AGENCE DE SÛRETÉ TUV convenance prise de courant deux lampes rétractables espacé permettre l utilisation de transformateurs prise de bnc lampe bnc lampe commutateur électrique banques d isolement de sortie à C A 10 pi 12 de mesure de cable électrique gradateur avant de lampe compteur bouton de contrôle...

Страница 16: ...icos de voltaje múltiples transitorios que requieren el desmantelamiento de su sistema y la reparación del supresor de sobretensión Esto no sucede con el SMP de Fur man Los voltajes transitorios perjudiciales se absorben se contienen y se disipan con seguridad Su equipo conectado está protegido mientras el SMP de Furman se protege a sí mismo Una característica única del SMP de Furman es el incompa...

Страница 17: ...ado El símbolo de relámpa go terminado en flecha sirve para alertar sobre la presencia de voltaje peligroso no aislado dentro del gabinete del equipo y puede tener la suficiente magnitud como para considerarlo un riesgo de descarga eléctrica INSTRUCCIONES IMPORTANTES DE SEGURIDAD Lea las siguientes instrucciones antes de la instalación 1 Lea y respete todas las instrucciones de seguridad y de func...

Страница 18: ...enos costosos Si se su pera la capacidad de corriente RMS de 20 amperios del PL PRO C el interruptor con tensión de resorte cambiará inmediatamente a la posición de apagado Usted deberá colocar el interruptor en la posición de encendido nuevamente una vez que se corrija el problema generalmente al eliminar un componente o hasta que la corriente RMS no exceda los 20 amperios o 2400 vatios INDICADOR...

Страница 19: ...inda una forma fácil de recargar varios accesorios electrónicos conocidos y dispositivos de comunicación por celular simplemente conectando el cable de recarga en el conector del panel delantero Tenga en cuenta que debido a que actualmente existen muchos estándares para USB es posible que algunos dispositivos no sean compatibles con nuestro cargador Presillas de seguridad para adaptadores de CA to...

Страница 20: ...igure la fecha de compra El comprador del producto deberá pagar por adelantado los cargos por el envío a la oficina central de Furman Furman deberá por su propia cuenta proporcionar un producto de reemplazo o bien a su entera discreción reparar el producto defectuoso Furman pagará los gastos de devolución del producto al comprador LA GARANTÍA ANTERIOR SUSTITUYE A TODAS LAS DEMÁS GARANTÍA EXPRE SAS...

Страница 21: ... de aluminio anodizado cepillado y negro de 0 120 0 32 cm placas de circuito impreso con vidrio epoxi CONSUMO DE ENERGÍA Aprox 15 VA LISTADO DE LA AGENCIA DE LA SEGURIDAD TUV tomacorriente para servicio dos lámparas retráctiles amplio espacio para enchufar adaptadores de ca conector bnc para la lampara interruptor del conector bnc bancos aislados de los enchufes de ca atenuador de luz botón del co...

Страница 22: ...22 PL PRO DMC OWNER S MANUAL Notes ...

Страница 23: ...23 FRANÇAIS ENGLISH EspaÑol Notes ...

Страница 24: ...1690 Corporate Circle Petaluma California USA 94954 Phone 877 486 4738 Fax 707 763 1310 www FurmanSound com PL PRODMC_RevA ...

Отзывы: