128
Personal emergency signal functions
Putting into operation
If the radio set is not offering the testing of individual sensors, either the pertinent
emergency signal function or the pertinent sensor test was not programmed.
If a sensor is detected as faulty, the remaining display content remains on
T
EST
. In
this case, logging into the personal emergency signal centre is not possible. Have
your radio set checked by a specialist and ensure it is not used before this check is
completed.
TIP
Ask the system administrator of your communication systems which personal emer-
gency signal functions are programmed on your radio set.
Perform the sensor test
In the following, all sensors that can be programmed on the radio set are listed. If an
emergency signal function is not programmed on the radio set, the test for the perti-
nent sensor is skipped without performing the test.
Prerequisite:
Your radio set is not in the charger.
The
S
ENSOR TEST
menu is displayed.
You can carry out the following work steps in any order.
Carry out the following work steps:
1.
P
RESSURE ALARM
sensor: Press the
‹Alarm›
key.
The display changes to
OK
if the sensor passes the test.
2.
W
ARNING ALARM
sensor: Press the
‹Function key 1›
key long.
The display changes to
OK
if the sensor passes the test.
3.
L
OCALISATION
sensor: Move the radio set near an inductive localisation beacon
(IOS) so it will receive a valid localisation signal.
The display changes to
OK
if the sensor passes the test.
4.
L
OSS ALARM
sensor: Remove and put the
‹tear-off contact›
into your pocket.
The display changes to
OK
if the sensor passes the test.
5.
N
O
-
MOTION ALARM
sensor: Move the radio set.
The display changes to
OK
if the sensor passes the test.
6.
T
IME ALARM
sensor: Press the
‹Right softkey›
key.
The display changes to
OK
if the sensor passes the test.
Содержание FT4
Страница 1: ...TETRA Radio Set Funkwerk FT4 S Operating Manual...
Страница 27: ......
Страница 30: ...26 Conformity and approvals EC declaration of conformity...
Страница 70: ...66 TETRA basics TETRA connection types...
Страница 142: ...138 Personal emergency signal functions Shutting down...
Страница 148: ...144 Technical data Side connector...
Страница 149: ......
Страница 150: ...Order no 5010930002 a V 1 2 2012 04 20...