![FunkTronic Major 4a Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/funktronic/major-4a/major-4a_manual_2346441028.webp)
m4a5a_v320_eng (14.02.2013)
- 28 -
Kompetent für Elektroniksysteme
m4a5a_v320_eng (14.02.2013)
- 29 -
Kompetent für Elektroniksysteme
Major 4a/5a:
Register 075: digit 1-4: tone sequence for alarm notification (ABC0)
digit 5: PTT for acknowledgement/request
5 = with pilot-tone
6 = without pilot-tone
7 = without pilot-tone, without TX
Register 076: configuration for alarm decoder
digit 1: type of alarm tone
digit 2: duration of alarm tone: n*200ms
digit 3: alarm tone volume
Register 077: configuration 2 for alarm decoder
digit 1: request at power-on y/n (1/0)
digit 2: number of switching output: 0 (none), 1-7
digit 3: switching output: 0(off),F(on), time is variable: 1...E(14) seconds
digit 4: acknowledgement: yes/no (1/0)
digit 5: display time 1-F = 1-15s, 0 = ends with acknowledgement (#-button)
It is also possible to program a button, so that an alarm query is sent to the FT634aC Line Inter-
face.
Function 2 (transmit call):
2
nd
digit:
6: transmit alarm query