![FunkTronic FT 635 UELE Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/funktronic/ft-635-uele/ft-635-uele_manual_2346452037.webp)
ft635ule_eng (21.06.2012)
- 36 -
- 37 -
ft635ule _eng(21.06.2012)
Kompetent für Elektroniksysteme
Kompetent für Elektroniksysteme
Selecting '3' allows the setting of the discriminator input.
poti adjustment (input of discriminator)
Enter 1000Hz at discriminator input with nominal level.
Adjust to 300mV.
Starting value: 047 (min:000 max:255) level: 0002 mV nominal
level: 300 mV
activate:
<+> : poti+1
<*> : poti+10
<-> : poti-1
<_> : poti-10
<a> : auto-adjustment
<p> : program
<x> : termination
currently: 047 level: 0002 mV
Selecting '4' allows the setting of the output to SUBout.
poti adjustment (output to SUBout)
starting value: 053 (min:000 max:255)
activate:
<+> : poti+1
<*> : poti+10
<-> : poti-1
<_> : poti-10
<p> : program
<x> : termination
currently: 053