Kompetent für Elektroniksysteme

Kompetent für Elektroniksysteme

be completely comprised in the tone sequence or it is composed of  variable digits in the 

tone sequence and fixed digits in the register. After the tone sequence has been identified 

correctly the line is seized and according to the configuration it will be checked if there is 

a call tone (see section Call tone detection). Then a signal tone is transmitted to the radio 

subscriber (see section Signal tone delay) and the number saved in the speed dial memory 

is automatically dialed in the desired dial mode.

The  call  is  automatically  terminated  by  modulation  monitoring  and  time  monitoring  or 

manually by an ending call.

The speed dial memory has 1000 entries with a length of 16 digits each. It is read and 

programmed  by the RS232 interface. The reading can be done either separately or as a 

block. Also the output can be done as plaintext or as a list for editing and uploading. With 

the help of a terminal program the outputs of the FT635UELE can be saved as a text file 

and can be processed later.  When uploading the speed dialing list the terminal program 

has to wait 10ms after each line before the next line can be transmitted.

The speed dial memory can contain all  characters for formating the telephone number. 

They are simply ignored when dialing. The numbers 0-9 are used as dial numbers and P 

as 1s dial pause. For DTMF-dial the DTMF-tones A-F are also allowed.

Speed dial functions:

WRxxx-yyy...display speed dial memory xxx (-yyy) (in plaintext)

WLxxx-yyy...display speed dial memory xxx (-yyy) (as a list for uploading)

WPxxx:yyyy...y..prog. speed dial memory xxx with y (max. 16 digits) 

WCxxx-yyy....delete speed dial memory xxx-yyy 

Maximum duration of a call

All  connections  are  terminated  after  N  seconds    at  the  latest,  if  they  have  not  been 

terminated before. At the beginning of the last 30 seconds an alarm tone is transmitted to 

the telephone subscriber. The maixmum duration of a call is adjustable from 1 to 9999s 

or can be turned off with 0. Ex factory it is set at 5 minutes (300s).

Reg.  Function

365  1.- 4. digit: maximum duration of call nnnn * 1s

Maximum transmission time for Simplex

If the maximum transmission time is exceeded, for example by loud noises in the telephone 

line, the telephone call will be terminated automatically. It is adjustable from 1 to 990s or 

can be  turned off with 0. Ex factory it is set at 45s.

Reg.  Function

366  1.- 3. digit: maximum transmission time for Simplex nnn * 1s

Maximum receiving time for Simplex

If the maximum receiving time is exceeded, for example by a constantly active carrier the 

telephone call will be terminated automatically. It is adjustable from 1 to 990s or can be 

turned off with 0. Ex factory it is set at 45s.

Speed dial memory

Call monitoring

Содержание FT 635 UELE

Страница 1: ...Telephone Line Interface FT 635 UELE Kompetent f r Elektroniksysteme...

Страница 2: ...ion Telephone Radio 13 Automatic Call Forwarding with Direct Call Tel Radio 14 Night Mode Telephone Radio 14 Direct Dialing with DTMF Radio Telephone 14 Radio Telephone 14 Direct Dialing with tone seq...

Страница 3: ...there is a 15 pole D Sub connector available the version in the FT635 system housing has the additional 37 pole D Sub connector The connection to the telephone network is made by a RJ11 connector The...

Страница 4: ...rom the radio to the telephone network resp from the telephone network to the radio 8 telephone line 2 two way radio telephone There are different applications for the operation of a FT635 UELE automa...

Страница 5: ...programmed at the first digit in register 056 Reg Function 056 2 digit configuration of the carrier input without carrier function if the 1 digit is programmed with 2 or 3 possible values 0 1 4 5 same...

Страница 6: ...It is adjustable from 0 to 990ms Ex factory it is set at 100ms Reg Function 055 3 4 digit transmitter follow up time nn 10ms The transmitter can be turned off by the transmission time limit The trans...

Страница 7: ...s in which their functions are programmed In the first register the function is programmed when activating the input input switches to ground and in the second register the function is programmed when...

Страница 8: ...er 097 1Fxxxxxx The digital outputs I O8 15 can be switched by transmitting certain 8 tone sequences from the radios In this process the first 5 digits of the 8 tone sequence are evaluated selectively...

Страница 9: ...gits the following applies 1 decoder at the RX input radio in of the UELE 2 decoder at the discriminator input discriminator in of the UELE To program the EEPROMs please read the section Programing mo...

Страница 10: ...r But the length of the individual tones can be adjusted separately After changing the tone sequence the duration of the tones also has to be reprogrammed This is not automatically carried out by the...

Страница 11: ...d tones 080 1 3 digit decoder maximum tone duration 1 tone nnn 5ms 080 4 5 digit decoder minimum tone duration of all tones nnn 5ms 080 6 digit tone sequence decoder at 1 radio AF 2 discriminator 081...

Страница 12: ...the 4 and 5 digit All following numbers of the tone sequence are dialed If in addition one or two specified prefix numbers are to be dialed before the direct dialing numbers this can be programmed at...

Страница 13: ...med with F Otherwise additional unused DTMF numbers must be entered After complete call input the call is either started with the end key on the telephone normally the key or automatically If not all...

Страница 14: ...tomatic transfer with direct call The only difference between night mode and normal operation is the use of different registers Switching from normal operation to night mode is done by a tone sequence...

Страница 15: ...gits in the DTMF starting call 0 7 358 2 7 digit code for starting call by DTMF When dialing directly with tone sequence telephone numbers with a defined length are dialed The length of the telephone...

Страница 16: ...number They are simply ignored when dialing The numbers 0 9 are used as dial numbers and P as 1s dial pause For DTMF dial the DTMF tones A F are also allowed Speed dial functions WRxxx yyy display spe...

Страница 17: ...e radio subscriber If the radio subscriber is not ready to receive immediately after transmission of the signaling which releases dialing tone sequence resp DTMF tone maybe the signal tone cannot be r...

Страница 18: ...io or telephone Enter the text number and the recording source in the monitor command If you want to record the texts from the telephone the telephone connection must be set up beforehand Then you sta...

Страница 19: ...digit of the tone sequence 4 digit 10 range speed dialing is at the 7 digit of the tone sequence 5 digit 1 range speed dialing is at the 8 digit of the tone sequence 6 8 digit unused as the digits com...

Страница 20: ...l tone detection after connecting to an external line has the effect that a dialing process beginning with the prefix number for an external line is only continued after the dial tone has been detecte...

Страница 21: ...ll progress tones are to be programmed the exact periods of time of the new call progress tones must be known To facilitate this the UELE can output the current times Ex factory the following tones ha...

Страница 22: ...Duplex operation a different input has to be used when the normal carrier input is needed see section In and outputs If T11 55 is active then UELE will delay the beginning of the call when the transmi...

Страница 23: ...f 2 AF carrier 3 phantom 4 low active pullup off 5 high active pullup on 2 digit configuration for carrier input for AF or phantom carrier 1 digit 2 or 3 0 low active pullup on 1 high active pullup of...

Страница 24: ...6 digit switching output and switching function 3 7 8 digit switching output and switching function 4 possible functions at 1 3 5 7 digit 0 no function 1 PTT output normal 2 PTT output inverted 3 TEL...

Страница 25: ...00 function input SQL passive active 141 00000000 function input SQL active passive 108 141 1 digit function type 0 no function 3 T11 55 input 9 night mode input function 3 T11 55 input 2 digit active...

Страница 26: ...t digit in the tone sequence for 10 range short dialing number 0 default number of digit 7 5 digit digit in the tone sequence for 1 range short dialing number 0 default number of digit 8 6 digit 100 r...

Страница 27: ...tone sequence digits with F are entered in the telephone 8 digit night mode tel radio on off 1 0 363 0F0F0000 configuration dialing tel radio 1 2 valid for direct dialing with DTMF register 361 1 digi...

Страница 28: ...decoder 2 4 digit nnn 10ms tone duration for continuous tone decoding 5 7 digit nnn 10ms pause duration for no tone decoding 8 digit indicate decoded exchange tone periods y n 1 0 381 399 exchange to...

Страница 29: ...t pulse duration nn 5ms on hook time 3 4 digit pulse duration nn 5ms off hook time 5 8 digit pause between 2 dial numbers nnnn 5ms 61100200020 duration of pulse dialing 1 4 digit pulse dialing duratio...

Страница 30: ...aw max 110ms 2 half the Baud rate max 110ms 3 A law and half the Baud rate max 220ms VOX 618 20051010 configuration VOX radio 1 2 digit minimum level for threshold AF gone AF present 00 99 3 4 digit m...

Страница 31: ...00010000 4 8 digit output level tone telephone 0 32768 624 00000000 4 8 digit output level pilot tone radio 0 32768 625 00006400 4 8 digit output level pilot tone telephone 0 32768 627 06000000 teleph...

Страница 32: ...placement on the connector sockets of the motherboard when installing it To do this the TIM should be aligned as shown in the following pictures front plate is on the left recess of the TIM circuit bo...

Страница 33: ...2 in output 8 I O 11 out input 7 I O 10 out input 6 I O 09 out input 5 I O 08 out input 4 GND out input 3 RS232 RxD input 2 RS232 TxD output 1 LED transmitting relay on LED pilot tone turned on 6 pole...

Страница 34: ...for 6c 6 I O I O 11 pull up 5V OUT radio CTCSS 7 I O I O 12 pull up 5V IN radio discriminator 8 I O I O 13 pull up 5V OUT bus AF RADIO BUS 9 I O I O 14 pull up 5V 10 I O I O 15 pull up 5V IN radio AF...

Страница 35: ...terminal program answers with the following display Online Monitor FT 635 UELE Pxxx yyyyyyyy Prog EEPROM Adr xxx to yyyyyyyy Rxxx Read EEPROM Adr xxx A Adjust Poti Ixxxxy Inbandtone xxxxHz 0 off y T F...

Страница 36: ...ut of radio Enter 1000Hz at radio input with nominal level Adjust at internal measuring point MP1 to 300mV Starting value 047 min 000 max 255 level 0002 mV nominal level 300 mV activate poti 1 poti 10...

Страница 37: ...level Adjust to 300mV Starting value 047 min 000 max 255 level 0002 mV nominal level 300 mV activate poti 1 poti 10 poti 1 _ poti 10 a auto adjustment p program x termination currently 047 level 0002...

Страница 38: ...35 UELE 635325 FT635 UELE 19 635090 Programmierkabel f r RS232 supply voltage 12 V weight ca 525 g dimensions width x depth x height 104 x 44 x 175 mm 19 dimensions 3 HE 7 TE input impedance radio 600...

Страница 39: ...e has not been turned off and all capacitors have been discharged Electrolytic capacitors can be still charged for a long time after turning off When using components modules devices or circuits and e...

Страница 40: ...ding chapters 28 10 08 register assignment revised in accordance with the latest software release 10 11 08 connection examples added 14 11 08 connection examples added 23 06 09 table of contents corre...