9. FAULT FINDING
Please see section 6.1-6.4 for fault testing.
If a fault warning occurs whilst using your Easiair
®
2020 Powered Air Kit, please consult the table below:
Fault
Probable reason
Recommendation
The blower unit
does not work
at all.
Entirely discharged battery
(verify if the blower unit works with
another charged battery).
Charge the battery
(if problem persists, check the battery).
Faulty motor, circuit board
or connector.
Contact your supplier.
Low airflow.
Blocked air hose or airduct.
Check and remove blockage.
Leakage.
Check all seals, connectors and the air hose. Make
sure that air cannot leak through holes or tears.
Battery is not charged enough.
Charge the battery
(if problem persists, check the battery).
Blocked filter or pre-filter.
Change the pre-filter. If the problem
persists change the main filter.
Short operating
time.
Clogged filter.
Change the filters.
Battery is not charged properly.
Charge the battery
(if problem persists, check the battery).
Battery cannot
be charged.
Battery contact is damaged.
Check the battery contact.
Charger is faulty.
Contact your supplier.
Battery cannot be
charged sufficiently.
Battery is worn out.
Install a new battery.