FULL MOON OPTICS REVELATION-40 Скачать руководство пользователя страница 8

 

1.  Normal start 

– the video recording module is completely off 

until you press REC button (8), then the module starts, taking 
approximately 15-20sec between pressing the REC button 
and actual start of video recording. This mode allows you to 
save the batteries when video recording is not desired, such 
as simple terrain orientation. 

2.  Quick start 

– the video recording module starts as soon as 

you power the scope and enters the standby mode. When 
REC button is pressed, video recording starts within 5 
seconds during the first recording and within 3 seconds 
thereafter. This mode allows you to start recording almost 
instantly and is useful when frequent shots are taken during 
hunt, or any time when video recording is frequently used. 
Please note during this mode additional battery power is used. 

See more information about video recording on Page-11 

12. Date and Time Stamp Position 

This setting allows user to select the on-screen position of the 
date and time during video recording. Four positions are available: 
Right Down 

– Left Down – Right Up – Left Up in addition OFF 

position is available, which removes date/Time Stamp from video 
recordings. 

13. Proximity Sensor 

The monocular is equipped with special Proximity Sensor, which 
detects the user’ face and can turn the monocular ON or in 
Standby Mode depending on the distance between the user face 
and proximity sensor. This menu option allows user to either turn 
the proximity sensor ON or OFF 

14. Proximity Sensor Range, mm 

This function allows user to select the desired distance between 
user’s face and proximity sensor that triggers monocular activation 
or standby. Range between 20mm and 99mm is provided.  

15. Auto Bad Pixel Correction 

This function allows the scope computer to automatically correct 
any bad pixel. For manual bad pixel correction, please refer to the 
next menu function and also to the BAD PIXEL CORRECTION 
instructions on page-12. 

IMPORTANT: DURING ANY BAD PIXEL CORRECTION PROCESS 

YOU MUST KEEP THE LENS COVER ON AT ALL TIMES AND WE 
STRONGLY RECOMMEND PLACING A DARK TAPE OVER THE 
PINHOLE IN THE LENS COVER.

 

THIS IS NECESSARY FOR A 

COMPLETELY UNIFORM DARK SCREEN DURING THE PROCEDURE.

 

16. Manual Bad Pixel Correction 

This function allows the user to correct any bad pixel that may 
appear during the use of the device, without having to return the 
scope to the factory. Please see page-12 for BAD PIXEL 
CORRECTION instructions   

Содержание REVELATION-40

Страница 1: ...1 REVELATION 40 LONG RANGE THERMAL IMAGING MONOCULAR OPERATION MANUAL Versions 10 0 26 13 0 27 13 0 28 IMPORTANT Please read this manual in its entirety PRIOR to using this device...

Страница 2: ...trical signal by the thermal sensor called microbolometer located inside the unit and that electrical signal is then displayed on the micro display located near the ocular eyepiece 2 Your device opera...

Страница 3: ...3 OPERATION REVELATION 40 MONOCULAR 10 2 1 8 15 11 3 4 5 6 7 9 13 14 12...

Страница 4: ...r thermal unit has a push Power button 11 To turn the unit ON first remove the objective lens cover and push the Power Button 11 for a little over one second Look through the eyepiece the unit will be...

Страница 5: ...l allow for better target detection and recognition of surroundings such as houses buildings trees and bushes and so on allowing you to better see the target surroundings and to better orient in the t...

Страница 6: ...en be turned off by long pressing the Super Controller again or the menu automatically turns off after 15 seconds of inactivity Main Menu Selections from top to bottom 1 User Profile There are 3 Custo...

Страница 7: ...ther conditions where targets will appear washed out against the background as well as during the situations where target heat is waning This is especially useful during search and rescue operations w...

Страница 8: ...removes date Time Stamp from video recordings 13 Proximity Sensor The monocular is equipped with special Proximity Sensor which detects the user face and can turn the monocular ON or in Standby Mode d...

Страница 9: ...nsparency of the On Screen Display Menu as well as reticle and status bar transparency 5 levels of transparency are available along with Zero transparency Each higher level of transparency makes menu...

Страница 10: ...reset all settings to factory levels We do not recommend using this function unless you feel that the scope is not functioning as it should If this happens and you need to reset the settings to factor...

Страница 11: ...e you must first activate the feature by pressing once the Rangefinder Button 4 You will see the shutter box appear in the display At this point you can aim at the viewing object and press the Rangefi...

Страница 12: ...directly into the input 7 or external power supply to the input 9 Once the external power supply is no longer needed remove the connection and replace the metal safety cap before you take the unit to...

Страница 13: ...NOTE broken USB connector is not covered under warranty 4a IF SUPPLIED WITH FACTORY USB ADAPTER CUP AND CABLE use the factory USB adapter cup and the factory cable for this task 5 Connect the USB side...

Страница 14: ...ark or click on open stream whichever option is currently showing on the app 7 For iOS smartphones in the lower left corner you will find a miniature screen click on this screen and it will open up fu...

Страница 15: ...ars to be washed out especially the surrounding areas You may be operating device in particularly humid conditions and need to increase either GAIN or IDE functions or both Refer to manual page 5 WARN...

Страница 16: ...______________________________ 10 Optical Magnification_________________________________________2 5x Digital Zoom _____________________________________________ 2x 4x Focusing Distance_________________...