FULL MOON OPTICS REVELATION-40 Скачать руководство пользователя страница 4

 

Glossary: 

– Laser Rangefinder Lens 

– Germanium Objective Lens (Protective Lens Cover) 

– Distance Focusing Wheel 

– Laser Rangefinder ON / Range Button 

– Invert Button 

– Zoom Button 

– Micro-USB Connector (Protective Cover) 

– REC (Video Recording) Button 

– External Power Supply Connector 

10 

– Eye Proximity Sensor 

11 

– Power ON-OFF / Standby Button 

12 

– Power LED Indicator 

13 

– Ocular Focusing Wheel 

14 

– Super Controller / MENU Access 

15 

– Battery Compartment (Cover) 

 

INSTALLING THE BATTERIES: 

Your thermal unit operates on commonly available 3V Lithium 
batteries, CR123-type.  You need 2 batteries to operate the device. 
Rechargeable batteries are OK, but their peak voltage cannot exceed 
4.2V each. 
To install the batteries, unscrew the battery compartment cover (15) 
and install the batteries inserting the positive (+) end first.  Once the 
batteries are inside, replace the cover. 

 

TURNING THE UNIT ON AND OFF: 

Your thermal unit has a push Power button (11). To turn the unit ON, 

first remove the objective lens cover and push the Power Button (11) 
for a little over one second.  Look through the eyepiece 

– the unit will 

become operational within approximately 4-5 seconds.  To turn the 
unit OFF push the same button for approximately 2 seconds.  Please 
note that you can enter Standby mode where the unit remains on, but 
the image display is turned off by pressing the Power Button just 
momentarily. The red LED power indicator (12) will remain lit during 
the standby mode.  Always replace the objective lens cover after the 
unit is turned off and is no longer is in use. 

 

FOCUSING THE UNIT: 

To obtain the sharp image, you must first rotate Ocular Focusing Ring 
(13) in either direction, until you notice in which position the image is 
at its best.  Since you are looking at a display, it will be easier to adjust 
the ocular by simply focusing your attention on the displayed letters 
and numbers.  After that, rotate the Distance Focusing Wheel (3) also 
until the image is at its best.  You may have to repeat the process 

Содержание REVELATION-40

Страница 1: ...1 REVELATION 40 LONG RANGE THERMAL IMAGING MONOCULAR OPERATION MANUAL Versions 10 0 26 13 0 27 13 0 28 IMPORTANT Please read this manual in its entirety PRIOR to using this device...

Страница 2: ...trical signal by the thermal sensor called microbolometer located inside the unit and that electrical signal is then displayed on the micro display located near the ocular eyepiece 2 Your device opera...

Страница 3: ...3 OPERATION REVELATION 40 MONOCULAR 10 2 1 8 15 11 3 4 5 6 7 9 13 14 12...

Страница 4: ...r thermal unit has a push Power button 11 To turn the unit ON first remove the objective lens cover and push the Power Button 11 for a little over one second Look through the eyepiece the unit will be...

Страница 5: ...l allow for better target detection and recognition of surroundings such as houses buildings trees and bushes and so on allowing you to better see the target surroundings and to better orient in the t...

Страница 6: ...en be turned off by long pressing the Super Controller again or the menu automatically turns off after 15 seconds of inactivity Main Menu Selections from top to bottom 1 User Profile There are 3 Custo...

Страница 7: ...ther conditions where targets will appear washed out against the background as well as during the situations where target heat is waning This is especially useful during search and rescue operations w...

Страница 8: ...removes date Time Stamp from video recordings 13 Proximity Sensor The monocular is equipped with special Proximity Sensor which detects the user face and can turn the monocular ON or in Standby Mode d...

Страница 9: ...nsparency of the On Screen Display Menu as well as reticle and status bar transparency 5 levels of transparency are available along with Zero transparency Each higher level of transparency makes menu...

Страница 10: ...reset all settings to factory levels We do not recommend using this function unless you feel that the scope is not functioning as it should If this happens and you need to reset the settings to factor...

Страница 11: ...e you must first activate the feature by pressing once the Rangefinder Button 4 You will see the shutter box appear in the display At this point you can aim at the viewing object and press the Rangefi...

Страница 12: ...directly into the input 7 or external power supply to the input 9 Once the external power supply is no longer needed remove the connection and replace the metal safety cap before you take the unit to...

Страница 13: ...NOTE broken USB connector is not covered under warranty 4a IF SUPPLIED WITH FACTORY USB ADAPTER CUP AND CABLE use the factory USB adapter cup and the factory cable for this task 5 Connect the USB side...

Страница 14: ...ark or click on open stream whichever option is currently showing on the app 7 For iOS smartphones in the lower left corner you will find a miniature screen click on this screen and it will open up fu...

Страница 15: ...ars to be washed out especially the surrounding areas You may be operating device in particularly humid conditions and need to increase either GAIN or IDE functions or both Refer to manual page 5 WARN...

Страница 16: ...______________________________ 10 Optical Magnification_________________________________________2 5x Digital Zoom _____________________________________________ 2x 4x Focusing Distance_________________...