background image

12 

 

expect batteries to discharge faster during active recording. 

If you plan to 

do extensive video recording

 during operation, it is advised to use an 

external 5V power bank with large capacity (over 10,000mA) and each USB 
output rated at least at 2V. Should the battery power get too low the video 
recording will automatically stop and warning message will appear advising 
that battery power is too low for video recording. The unit may still be 
operated for some time in normal non-video recording mode. 

See more 

details on Video Record Modes selection on Page-7

 

 

IMPORTANT:

 when finished recording you must always press REC button 

once again to save the recording. 
 

 

EXTERNAL POWER SUPPLY: 

It is possible to connect an optional external 5V power bank

 

to the 

monocular through the micro-USB connector (7) or an external power supply 
through the external power supply connector (9) in order to operate it for a 
longer periods of time. Please make sure only 5V power bank is used 
through the USB connector and output power should be at least 2A for each 
output. For the External Power Supply connection (9) please make sure the 
output power is not higher than 9V.  

NOTE: do not connect to AC/DC 

outlets such as wall sockets or car cigarette adapters!

 To connect an 

external power supply, remove the safety cap (7 or 9 depending on which 
connection you are utilizing) by unscrewing it counter-clockwise and either 
connect the micro-USB cable directly into the input (7), or external power 
supply to the input (9). Once the external power supply is no longer needed, 
remove the connection and replace the metal safety cap before you take the 
unit to the field 
 

BAD PIXEL CORRECTION: 

IMPORTANT: DURING ANY BAD PIXEL CORRECTION PROCESS YOU 

MUST KEEP THE LENS COVER ON AT ALL TIMES AND WE 
STRONGLY RECOMMEND PLACING A DARK TAPE OVER THE 
PINHOLE IN THE LENS COVER.

 

THIS IS NECESSARY FOR A 

COMPLETELY UNIFORM DARK SCREEN DURING THE PROCEDURE.

 

 
Your device comes with a unique feature allowing you to manually correct any bad 
pixels that may develop during the course of time. To do that, press and hold Super 
Controller (14) to enter the main menu. Then rotate the Super Controller counter-
clockwise until “Bad Pixel Correction” is highlighted. Then short-press the Super 
Controller to enter the pixel correction mode. The white crosshairs with flashing dot 
in the center will be displayed. Now you can rotate the Super Controller to direct the 
flashing dot to the bad pixel (to change between horizontal movement and vertical 
movement short-press the Super Controller.  Once the flashing dot is over the bad 
pixel, press ZOOM button (6) and bad pixel will be corrected. You may need to 
press ZOOM more than once. Should you have a bad spot larger than one pixel, 
you must work each pixel one at a time, starting from outside pixels and then 
moving to the inside pixels. After all bad pixels are corrected, long-press the Super 
Controller until it enters Main Menu. NOTE: if you do not perform this function, bad 
pixel corrections will not be saved and you will have to perform the corrections again 

Содержание REVELATION-40

Страница 1: ...1 REVELATION 40 LONG RANGE THERMAL IMAGING MONOCULAR OPERATION MANUAL Versions 10 0 26 13 0 27 13 0 28 IMPORTANT Please read this manual in its entirety PRIOR to using this device...

Страница 2: ...trical signal by the thermal sensor called microbolometer located inside the unit and that electrical signal is then displayed on the micro display located near the ocular eyepiece 2 Your device opera...

Страница 3: ...3 OPERATION REVELATION 40 MONOCULAR 10 2 1 8 15 11 3 4 5 6 7 9 13 14 12...

Страница 4: ...r thermal unit has a push Power button 11 To turn the unit ON first remove the objective lens cover and push the Power Button 11 for a little over one second Look through the eyepiece the unit will be...

Страница 5: ...l allow for better target detection and recognition of surroundings such as houses buildings trees and bushes and so on allowing you to better see the target surroundings and to better orient in the t...

Страница 6: ...en be turned off by long pressing the Super Controller again or the menu automatically turns off after 15 seconds of inactivity Main Menu Selections from top to bottom 1 User Profile There are 3 Custo...

Страница 7: ...ther conditions where targets will appear washed out against the background as well as during the situations where target heat is waning This is especially useful during search and rescue operations w...

Страница 8: ...removes date Time Stamp from video recordings 13 Proximity Sensor The monocular is equipped with special Proximity Sensor which detects the user face and can turn the monocular ON or in Standby Mode d...

Страница 9: ...nsparency of the On Screen Display Menu as well as reticle and status bar transparency 5 levels of transparency are available along with Zero transparency Each higher level of transparency makes menu...

Страница 10: ...reset all settings to factory levels We do not recommend using this function unless you feel that the scope is not functioning as it should If this happens and you need to reset the settings to factor...

Страница 11: ...e you must first activate the feature by pressing once the Rangefinder Button 4 You will see the shutter box appear in the display At this point you can aim at the viewing object and press the Rangefi...

Страница 12: ...directly into the input 7 or external power supply to the input 9 Once the external power supply is no longer needed remove the connection and replace the metal safety cap before you take the unit to...

Страница 13: ...NOTE broken USB connector is not covered under warranty 4a IF SUPPLIED WITH FACTORY USB ADAPTER CUP AND CABLE use the factory USB adapter cup and the factory cable for this task 5 Connect the USB side...

Страница 14: ...ark or click on open stream whichever option is currently showing on the app 7 For iOS smartphones in the lower left corner you will find a miniature screen click on this screen and it will open up fu...

Страница 15: ...ars to be washed out especially the surrounding areas You may be operating device in particularly humid conditions and need to increase either GAIN or IDE functions or both Refer to manual page 5 WARN...

Страница 16: ...______________________________ 10 Optical Magnification_________________________________________2 5x Digital Zoom _____________________________________________ 2x 4x Focusing Distance_________________...