background image

Rev. 03

10.2 Connection Scheme

- Base Module

Fastening the base module with screws*;

Panel

91mm

45mm

To place the frontal module 
on the control panel, press 
until it engages;

2

To  release  it,  just  press  the  side 
locks;

3

Remove the controller 
from the front control 
panel;

10. INSTALLATION

10.1 Fastening of frontal and base modules
- Frontal Module

Make the cut in the control panel by taking 
the given measures. Please refer to item 3;

1

ENVIRONMENTAL INFORMATION

Packaging:

The materials used in Full Gauge products' packaging are 100% recyclable. Dispose of your 
waste preferably using specialized recycling agents.

Product:

The components used in Full Gauge controllers can be recycled and reused if disassembled 
by a specialized company.

Disposal:

Do not burn or throw controllers in domestic garbage. Obey the laws in effect for your area 
regarding the disposal of electronic waste. If in doubt, please contact Full Gauge Controls.

11. IMPORTANT

According to the chapters of the NBR 5410 regulations:

1:

 Install overvoltage protectors at the power supply

2:

 Sensors and serial communication cables can go together, but not in the same conduit 

through which power supply and charge activation pass.

3:

 Install transient suppressors (RC filter) parallel to the charges in order to increase the life of 

the relays.

Suppressors wiring diagram on 

contactors

Suppressor

A1

A2

A1 and A2 are the terminals
of the contactor coil. 

Suppressors wiring diagram on direct 

activation charges

Load

Suppressor

For direct activation, consider 
the maximum current specified.

Full Gauge Controls offers suppressors for sale

*  The 

S1  sensor

  must  be  in  the  ambient  (black).

**The 

S2 sensor

 must be secured on the evaporator 

by the metallic clamp (gray).

- Base Module

- Frontal Module

 (Power supply and common 

of the relays)

Light 

(LIGHT)

Compressor 

(COMP)

Defrost 

(DEFR)

Power supply

115 Vac 

(or in the version 

230 Vac)

Fan

(FANS)

Interconnection Cable

Sensor S1*

Sensor S2**

Digital input

 (Door Switch)

*screws not included;

Copyright 2014

W

ARRANTY

 - FULL

 GAUGE CONTROLS

Products  manufactured  by  Full  Gauge  Controls,  as  of  May  2005,  have  a  two  (02)  year 

warranty, as of the date of the consigned sale, as stated on the invoice. They are guaranteed 
against manufacturing defects that make them unsuitable or inadequate for their intended use.

EXCEPTIONS TO WARRANTY

The Warranty does not cover expenses incurred for freight and/or insurance when sending 

products with signs of defect or faulty functioning to an authorized provider of technical support 
services. The following events are not covered either: natural wear and tear of parts; external 
damage caused by falls or inadequate packaging of products.

LOSS OF WARRANTY

Products will automatically lose its warranty in the following cases:
-  The  instructions  for  assembly  and  use  found  in  the  technical  description  and  installation 

procedures in Standard IEC60364 are not obeyed;

- The product is submitted to conditions beyond the limits specified in its technical description;
- The product is violated or repaired by any person not a member of the technical team of Full 

Gauge Controls;

- Damage has been caused by a fall, blow and/or impact, infiltration of water, overload and/or 

atmospheric discharge.

USE OF WARRANTY

To  make  use  of  the  warranty,  customers  must  send  the  properly  packaged  product  to  Full 

Gauge Controls together with the invoice or receipt for the corresponding purchase. As much 
information as possible in relation to the issue detected must be sent to facilitate analysis, testing 
and execution of the service.

These procedures and any maintenance of the product may only be provided by Full Gauge 

Controls Technical Support services in the company's headquarters at Rua Júlio de Castilhos, 
250 - CEP 92120-030 - Canoas - Rio Grande do Sul – Brasil

Содержание MT-444 eXpress

Страница 1: ...ss and hold for 10 sec release the key On Off release the key On Off 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Power Saving Mode LED indicator Light LED indicators LED indicator for pre defrost and defrost on or draining blinking Fan LED indicators Compressor LED indicators Power Saving Mode Key Temperature unit LED indicator Plus Key Preset 1 Set Key Preset 2 Minus Key Preset 3 DIGITAL COOLING CO...

Страница 2: ... mode Example If adjusted t1 4 0 and h1 1 0 the compressor will be turned off when the S1 sensor temperature ambient is less than 4 0 and it will be turned on whenitishigherthan 5 0 4 0 1 0 ThisisthedifferencebetweenturningcoolingOFFandBACKONinpower savingmode FUNCTION 50 58 60 99 ºC F 6 0 21 50 58 60 99 ºC F 50 58 0 1 01 8 0 14 ºC F 3 0 05 50 58 60 99 ºC F 1 0 30 50 58 60 99 ºC F 2 0 36 50 58 60 ...

Страница 3: ...ivatedtogetherwiththecompressor This is the amount of time the fan will remain ON if F1 and F2 are configured as automatic whilethecompressorisoff 50 58 60 99 ºC F 5 0 23 no 99 min 10 no 99 min no 50 58 60 99 ºC F 40 99 50 58 60 99 ºC F 20 68 1 99 H 12 1 99 min 30 no 99 min 15 OF On OF no 99 min 1 A d d 1 99 min 1 d3 d4 d5 Determines how often defrost will be performed which is the time counted fr...

Страница 4: ...2 10 10 V 0 2 30 s 4 no 48 H no 0 1 01 20 36 ºC ºF 10 18 0 1 01 50 90 ºC ºF 50 90 no 99 min 1 P3 M Time in minutes H Time in hours M H m F4 F5 F6 F7 F8 P1 P2 This is the amount of time the fan will remain OFF if F1 and F2 are configured as automatic whilethecompressorisoff The fan can be set to remain activated or deactivated in the period when the door is kept open The purpose of this function is...

Страница 5: ...ard If no key is pressed within 10 seconds the keyboard will be hidden again This prevents unwantedactivationsfrombeingperformed 1 The keys always remain on In this mode the first touch is enough to perform functions no 2 no 0 1 0 When control functions are shutdown the controller starts to operate purely as a temperature indicator with all outputs deactivated This function can operate in the foll...

Страница 6: ...essor COMP Defrost DEFR Power supply 115 Vac or in the version 230 Vac Fan FANS Interconnection Cable Sensor S1 Sensor S2 Digital input Door Switch screws not included Copyright 2014 WARRANTY FULL GAUGE CONTROLS Products manufactured by Full Gauge Controls as of May 2005 have a two 02 year warranty as of the date of the consigned sale as stated on the invoice They are guaranteed against manufactur...

Отзывы: