92
OPTIONAL EQUIPMENT EXHAUST BYPASS UNIT
■
Optional Equipment Exhaust Bypass Unit (EBU-600)
○
Summary:
The exhaust bypass unit prevents water/ oil remaining in the work part from entering the air leak
tester. Air leak testers require high sensitivity and accuracy in order to detect very minute leaks,
therefore it is important that we only use clean air.
Connecting an air filter to the air supply port can eliminate the intrusion of foreign substances, but
since the air charged into the work is then released into the atmosphere through the air leak tester,
any water, oil, etc. inside the work will be released into the air leak tester along with the exhausted air.
Because of this, we recommend using an exhaust bypass unit to prevent intrusion related problems
from occurring.
Explanations in this manual are done under the assumption that the master is a standard part. If
foreign material could enter into the master (such as from the work or work comparison,) take proper
precautions to ensure that this does not happen. (This option is not available in the H1 range).
○
External View
○
Installation Dimensions (Not including projecting items)
For more details, please refer to the Exhaust Bypass Unit External View supplement in the back of
this manual.
○
EXT VALVE SIGNAL Cable Wire
Connection
Tester Side
(EXH VALVE
SIGNAL)
Exhaust Bypass
Side
(EXT SIGNAL)
Applied
Connector
MR-34LF
JR16WR-7P
Remarks
2
-
3
24
-
4
External
Valve
10
13
19
Pin Number
32
Applied
Connector
(Included)
Plug JR16WR-7P
Receptacle JR16WP-7S
Applied Cable
Cable at least 0.3SQ
Label
Caution
・
Do not remove the EBU cover.
・
Some parts within the EBU carry a high voltage and
may be driven unexpectedly due to the tester’s
mechanical sequences. Possible electric shock and
injuries may occur if this warning is ignored. Only
qualified maintenance personnel should service these
machines.
142.5
82
4-M5
Approx 41
128
64
Height 113mm
Jumper
Содержание FL-601 Series
Страница 10: ...9 OUTLINE ...
Страница 17: ...16 OUTLINE ADDITIONAL EQUIPMENT MEMO ...
Страница 18: ...17 PRINCIPLE ...
Страница 24: ...23 POWER ON PROCEDURE ...
Страница 50: ...49 BASIC OPERATION ...
Страница 59: ...58 TESTING OPERATION ...
Страница 68: ...67 MAINTNANCE FUNCTIONS ...
Страница 92: ...91 OPTIONAL EQUIPMENT ...
Страница 108: ...111 SUPPLEMENT ...
Страница 112: ...111 SUPPLEMENT ...
Страница 116: ...115 SUPPLEMENT Pneumatic Circuit Diagram FL 601UL L M H1Pneumatic Circuit Diagram ...
Страница 119: ...118 SUPPLEMENT Pneumatic Circuit Diagram ChargeBypassUnit CBU 600C Exhaust Valve ...