- (01-19) -
4-1-3. HEAT EXCHANGE VENTILATION AND NORMAL
VENTILATION
HEAT EXCHANGE VENTILATION
External air is heat-exchanged with indoor air, and supplied
indoors after the temperature is made closer to the room
temperature
NORMAL VENTILATION
External air is let in without heat-exchange with indoor air.
ATTENTION
When the heating function is on during winter, do no use “normal ventilation.” The dew condensation will take place in the
unit, which may result in stains on the ceiling, etc.
Stale indoor air to be ex-
hausted (EA)
Fresh external air to be
supplied indoors (SA)
Outdoor
Indoor
Total heat
exchanger
Stale indoor air
(RA)
Fresh external
air (OA)
Fresh external air to be
supplied indoors (SA)
Stale indoor air to be
exhausted (EA)
Outdoor
Indoor
Stale Indoor air
(RA)
Fresh external
air (OA)
Total heat
exchanger