background image

En-1

INSTALLATION MANUAL

PART NO. 9373328162-04
AIR CONDITIONER REMOTE CONTROLLER
(WIRED TYPE)

Contents

1. SAFETY 

PRECAUTIONS 

.............................................. 1

2. ACCESSORIES 

............................................................. 1

3. ELECTRICAL 

REQUIREMENT 

...................................... 1

4.  SELECTING AN INSTALLATION LOCATION

4.1. Dimensions ............................................................. 2
4.2.  Name of parts ......................................................... 2

5.  INSTALLING THE REMOTE CONTROLLER

5.1.  Installation .................................................................. 3
5.2.  Setting the DIP switch ............................................ 3
5.3.  Connection of Remote Controller Cable ................. 4

6. INSTALLATION 

METHODS

6.1. Group control .......................................................... 4
6.2.  Dual remote control ................................................ 4

7.  TURNING ON THE POWER .......................................... 5
8.  SETTING THE ROOM TEMPERATURE 

DETECTION LOCATION .................................................. 5

9. FUNCTION 

SETTING 

.................................................... 5

10. TEST OPERATION ........................................................ 7
11. ERROR CODES ............................................................ 8

1. SAFETY PRECAUTIONS

Let the customer keep this installation manual because it is needed 

• 

when the air conditioner or remote controller is serviced or moved.

WARNING

This mark indicates procedures which, if improp-
erly performed, might lead to the death or serious 
injury of the user.

For the air conditioner to operate satisfactorily, install it as outlined in 

• 

this installation manual.
Installation work must be performed in accordance with national wiring 

• 

standards by authorized personnel only.
Do not turn on the power until all installation work is complete.

• 

CAUTION

This mark indicates procedures which, if improp-
erly performed, might possibly result in personal 
harm to the user or damage to property.

When detecting the room temperature using the remote controller, 

• 

please set up the remote controller according to the following 

conditions. If the remote controller is not located properly, the correct 

room temperature will not be detected, and thus abnormal conditions 

like “not cooled” or “not heated” will occur even if the air conditioner is 

running normally.

Locate where an average temperature 

• 

for the room being air-conditioned will be 

sensed.
Do not locate directly exposed to the outlet 

• 

air from the air conditioner.
Locate out of direct sunlight.

• 

Locate away from the in

fl

 uence of other 

• 

heat sources.

Do not touch the remote controller PC board and 

• 

PC board parts directly with your hands.
Do not wire the remote controller cable and the bus wire together with 

• 

or parallel to the connection cables, transmission cables, and power 

supply cables of the indoor and outdoor units. It may cause erroneous 

operation.
When installing the bus wire near a source of electromagnetic waves, 

• 

use shielded wire.
Do not set the DIP switches, either on the air conditioner or the remote 

• 

controller, in any way other than indicated in this manual or the manual 

that is supplied with the air conditioner. Doing so may result in an 

improper operation.

Temperature sensor

2. ACCESSORIES

The following installation parts are supplied. Use them as required.

Name and Shape

Q’ty

Application

Installation manual

1

This manual

Operating manual

1

Instruction book for operation

Remote controller cable

1

For connecting the remote 
controller 

Connecting cable 

1

For connecting the remote control-
ler cable to the wall mounted type 
and the 

fl

 oor type indoor unit

Tapping screw (M4 x 16mm)

2

For installing the remote controller

Binder

1

For remote controller and remote 
controller cable binding

Tapping screw (M4 x 14mm) 

1

For installing the remote controller 
cable to the indoor unit

Cable clamper 

1

For installing the remote controller 
cable to the indoor unit

3. ELECTRICAL REQUIREMENT

When connecting the remote controller use the following wiring.

Cable

Cable size

Remarks

Remote controller 

cable

22AWG

Sheathed PVC cable, 

Polar 3 core 

Use Sheathed PVC 

cable in accordance with 

local rules for cable.

*  We recommend that you purchase our service parts for the remote control-

ler cable. Contact service personnel to purchase this. 

9373328162-04_IM.indb   Sec1:1

9373328162-04_IM.indb   Sec1:1

2011-12-5   14:29:24

2011-12-5   14:29:24

Содержание UTY-RNN*M series

Страница 1: ...our le personnel agréé uniquement MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала INSTALLATIONSANLEITUNG Nur für autorisiertes Personal MANUAL DE INSTALACIÓN Solo para personal autorizado MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MONTAJ KILAVUZU Yetkili...

Страница 2: ...m being air conditioned will be sensed Do not locate directly exposed to the outlet air from the air conditioner Locate out of direct sunlight Locate away from the influence of other heat sources Do not touch the remote controller PC board and PC board parts directly with your hands Do not wire the remote controller cable and the bus wire together with or parallel to the connection cables transmis...

Страница 3: ...ensor Button 14 Maintenance Filter Reset Button 15 Operation Lamp 16 Day Display 17 Operation Lock Display 18 Temperature Display 19 Fan Speed Display 20 Timer Mode Display 21 Operation Mode Display 22 Timer and Clock Display 23 Filter Display 24 Economy Display 25 Thermo Sensor Display 26 Vertical Swing Display 27 Horizontal Swing Display 28 Defrost Display 4 SELECTING AN INSTALLATION LOCATION 4 ...

Страница 4: ... memory will be deleted if there is a power failure Factory setting 5 INSTALLING THE REMOTE CONTROLLER 5 1 Installation 5 1 1 INSTALLING THE REMOTE CONTROLLER Open the operation panel on the front of the remote controller remove the 2 screws indicated in the following figure and then remove the front case of the remote controller When installing the remote controller remove the connector from the ...

Страница 5: ...roller cable 20 mm 5 3 2 WHEN CONNECTING TO THE EXCLUSIVE TERMINAL BLOCK Connect the end of remote controller cable directly to the exclusive terminal block Terminal block M4 screw 3 2 1 Earth Ground the remote controller if it has an earth a ground wire Black White Red Indoor unit side PCB Indoor unit Outdoor unit power supply terminal block Remote controller terminal block Remote controller cabl...

Страница 6: ...re value between the temperature sensor of the indoor unit and the temperature sensor of the remote controller varies significantly it is likely to return to the control status of temperature sensor of the indoor unit temporarily As the temperature sensor of remote controller detects the temperature near the wall when there is a certain difference between the room temperature and the wall temperat...

Страница 7: ...s in the room If you do not wish the filter sign to be displayed select the setting value for No indication Factory setting Setting Description Function Number Setting Value Standard 11 00 Long interval 01 Short interval 02 No indication 03 The filter sign interval time is different according to Indoor unit type as follows Setting Description Compact Cassette Slim Duct Compact Wall Mounted Wall Mo...

Страница 8: ...3 11 External input control Operation Stop mode or Forced stop mode can be elected Factory setting Setting Description Function Number Setting Value Operation Stop mode 46 00 Setting forbidden 01 Forced stop mode 02 12 Room temperature control switching Only for Wired remote controller This setting is used to set the room temperature control method when the wired remote controller is selected by t...

Страница 9: ... Ex Middle temp sensor error 5 1 Indoor unit fan motor error 5 3 Drain pump error 5 7 Damper error 5 15 Indoor unit error 6 2 Outdoor unit main PCB model information error or communication error 6 3 Inverter error 6 4 Active filter error PFC circuit error 6 5 Trip terminal L error 6 10 Display PCB microcomputers communication error 7 1 Discharge temp sensor error 7 2 Compressor temp sensor error 7...

Страница 10: ......

Отзывы: